4-12
Sect
ion 4
APPLICATION SETTING EX
AMPLE
S
ZS-MDC
User’s Manual
Section 4
Measuring the Average Height
Measuring the Average Height
This is an example of how to measure the height at 3 locations on a workpiece, and
calculate the average of each measured height value. [AVERAGE] is used as the
operation mode.
For details on how to connect and install the Sensor Heads and Sensor Controllers, refer to the “ZS-L
User’s Manual”.
FUN Mode-[SENSING]-[SEL CH]
1.
Assign the CH No. of the controller to inputs
A to C to be used for the expression.
INPUT A:1CH
INPUT B:2CH
INPUT C:3CH
Press MENU key - ESC key.
2.
Select [TASK1].
Input A
Input B
Input C
Input A Input B Input C
CH0 CH1 CH2 CH3
The operation and/or measurement results are output
as judgement output or linear output.
▲
1
INPUT A
3
INPUT C
2
INPUT B
▲
1
TASK1
3
TASK3
2
TASK2
4
TASK4