![background image](http://html1.mh-extra.com/html/omron/v780-series/v780-series_user-manual_743948332.webp)
8 Browser Interface
8 - 42
UHF RFID System V780-series Reader/Writer User’s Manual (Z389)
Multi-ReaderWriter-
Setting
Multi-ReaderWriter
Mode
This is the Multi-Reader/Writer setting. It is
given as a decimal value.
0: Disabled
1: Enabled (Communications range
expansion mode)
0
NumberOfSlave
ReaderWriters
This is the number of connected slave
Reader/Writers. It is given as a decimal
value.
1 to 7
0
SlaveReaderWriter1
_IPAddress
This is the fixed IP address setting of slave
Reader/Writer 1. It is given as four decimal
numbers separated by periods.
0.0.0.0
SlaveReaderWriter2
_IPAddress
This is the fixed IP address setting of slave
Reader/Writer 2. It is given as four decimal
numbers separated by periods.
0.0.0.0
SlaveReaderWriter3
_IPAddress
This is the fixed IP address setting of slave
Reader/Writer 3. It is given as four decimal
numbers separated by periods.
0.0.0.0
SlaveReaderWriter4
_IPAddress
This is the fixed IP address setting of slave
Reader/Writer 4. It is given as four decimal
numbers separated by periods.
0.0.0.0
SlaveReaderWriter5
_IPAddress
This is the fixed IP address setting of slave
Reader/Writer 5. It is given as four decimal
numbers separated by periods.
0.0.0.0
SlaveReaderWriter6
_IPAddress
This is the fixed IP address setting of slave
Reader/Writer 6. It is given as four decimal
numbers separated by periods.
0.0.0.0
SlaveReaderWriter7
_IPAddress
This is the fixed IP address setting of slave
Reader/Writer 7. It is given as four decimal
numbers separated by periods.
0.0.0.0
SlaveReaderWriter1
_ReadTransmission
Power
This is the transmission power setting for
communications commands of the slave
Reader/Writer 1 read system. It is given as a
decimal value.
15 to 27: 15 to 27 dBm
27
SlaveReaderWriter1
_WriteTransmission
Power
This is the transmission power setting for
communications commands of the slave
Reader/Writer 1 write system. It is given as a
decimal value.
15 to 27: 15 to 27 dBm
27
SlaveReaderWriter2
_ReadTransmission
Power
This is the transmission power setting for
communications commands of the slave
Reader/Writer 2 read system. It is given as a
decimal value.
15 to 27: 15 to 27 dBm
27
SlaveReaderWriter2
_WriteTransmission
Power
This is the transmission power setting for
communications commands of the slave
Reader/Writer 2 write system. It is given as a
decimal value.
15 to 27: 15 to 27 dBm
27
SlaveReaderWriter3
_ReadTransmission
Power
This is the transmission power setting for
communications commands of the slave
Reader/Writer 3 read system. It is given as a
decimal value.
15 to 27: 15 to 27 dBm
27
Section name
Entry name
Description
Default
Summary of Contents for V780 Series
Page 22: ...Version Upgrade Information 20 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Page 60: ...3 Part Names and Functions 3 14 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Page 152: ...6 Functions 6 76 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Page 334: ...8 Browser Interface 8 44 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Page 358: ...9 Troubleshooting 9 24 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Page 392: ...Appendices A 30 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Page 393: ...I 1 I UHF RFID System V780 series Reader Writer User s Manual Z389 Index ...
Page 397: ......