![background image](http://html1.mh-extra.com/html/omron/v780-series/v780-series_user-manual_743948361.webp)
10 - 3
10 Maintenance and Inspection
UHF RFID System V780-series Reader/Writer User’s Manual (Z389)
1
0-1 Main
ten
ance a
nd In
spe
c-
tio
n
10
3
Panel condition
---
(A)
Ventilation
(A)
Check that the sys-
tem is ventilated
properly with natu-
ral ventilation,
forced ventilation,
or cooling air.
(A)
The interior tem-
perature must be
within a range
between -10 and
55°C with proper
ventilation.
(B)
Damage to pack-
ing for any enclos-
ing structure
(B)
Make sure that the
panel packing is
properly attached
with no damage.
(B)
The packing must
have no damage.
4
Mounting condition
(1) Make sure that the
Reader/Writer is
securely mounted.
No loose screws
---
(2) Make sure that each
connector is fully
inserted.
Each connector must be
locked or securely tight-
ened with screws.
---
(3) Make sure that no
wire is broken or
nearly broken.
Must be no wire that is
broken or nearly broken.
---
No.
Inspection item
Details
Criteria
Remarks
Summary of Contents for V780 Series
Page 22: ...Version Upgrade Information 20 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Page 60: ...3 Part Names and Functions 3 14 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Page 152: ...6 Functions 6 76 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Page 334: ...8 Browser Interface 8 44 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Page 358: ...9 Troubleshooting 9 24 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Page 392: ...Appendices A 30 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Page 393: ...I 1 I UHF RFID System V780 series Reader Writer User s Manual Z389 Index ...
Page 397: ......