Preparing and connecting wires:

This receptacle can be wired using side wire terminal screws or 
through backwire openings. Choose appropriate wire stripping 
specifications accordingly.

WARNING: 

TO AVOID FIRE SHOCK OR DEATH; TURN 

OFF POWER 

at circuit breaker or fuse and test that power is off 

before wiring!

Identifying your wiring application (most common):

NOTE:

 If the wiring in your wall box does not resemble any of 

these configurations, consult a qualified electrician.

WARNINGS AND CAUTIONS

:

• 

TO AVOID FIRE SHOCK OR DEATH; TURN OFF POWER 

at circuit breaker or fuse and test that power is off before wiring!

•  To be installed and/or used in accordance with electrical codes and regulations.
•  If you are unsure about any part of these instructions, consult an electrician.
•  To ensure that there is adequate room for wires, we recommend using at a minimum 3-1/2 inch deep wallboxes. For single-gang applications, this would be at a 

minimum an 18-cubic inch wallbox.

WARNINGS AND CAUTIONS

:

•  Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
•  Maximum wire length cannot exceed 300 ft (90 m).
•  Use this device 

with copper or copper clad wire only

.

•  Not for use with Vizia RF

®

 lighting systems.

Duplex Receptacle (Top Controlled)

Scene Capable Receptacle

Cat. No. DZR15 - 15A - 125VAC, 60Hz

Incandescent-1800W – Magnetic Low-Voltage-1800VA (1440W)

Electronic Low-Voltage-1800W – Fluorescent-1800VA – Supplemental-1/2 HP

INSTALLATION INSTRUCTIONS

DI-000-DZR15-02A

 TOOLS NEEDED TO INSTALL YOUR RECEPTACLE

Slotted/Phillips Screwdriver 

Electrical Tape 

Pliers 

 

Pencil 

  Cutters 

 Ruler

Changing the color of your Receptacle:

Your Receptacle includes three color options. The Receptacle ships with the 
White frame attached. To change color of frame, proceed as follows:

INSTALLING YOUR RECEPTACLE

NOTE:

 Use check boxes           when Steps are completed.

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

 

Step 1

2

4

3

1

Single Pole

1.

  Line (Hot)

2.

  Neutral

3.

  Ground

 

Step 2

Single Pole Wiring Application:

 

Step 3

•  Make sure that the ends of the wires from the wall box are 

straight (cut if necessary).

•  Remove insulation from each wire in the wall box as shown.

5/8" 

(1.6 cm)

Strip Gage 
(measure bare 
wire here)

Cut 

(if necessary)

Side Wire Connection 

Side wire terminals accept #14-12 
AWG 

solid copper wire only

.

Back Wire (either hole may be used) 

Back wire openings accept #14-12 
AWG 

solid copper wire only

.

WIRING RECEPTACLE:
Connect wires per WIRING DIAGRAM as follows:

•  Green or bare copper wire in wall box to Green terminal screw.
•  Line Hot wall box wire to terminal screw marked "LINE".
•  Line Neutral wall box wire to terminal screw marked "NEUTRAL".
• 

Proceed to Step 5.

Leviton’s Decora

®

 Z-Wave

®

 control

 components are designed to 

communicate with each other via Radio Frequency (RF) to provide remote 
control of your lighting. In a Z-Wave

®

 network, each device is designed 

to act as a router. These routers will re-transmit the RF signal from one 
device to another until the intended device is reached. This ensures 
that the signal is received by its intended device by routing the signal 
around obstacles and radio dead spots. The Scene Capable Electronic 
Receptacle is compatible with most Z-Wave

®

 enabled networks, from 

different manufacturers and can also be used with other devices displaying 
the Z-Wave

®

 logo.

WARNING: 

TO AVOID FIRE, PERSONAL INJURY OR DEATH DO NOT 

USE

 the remote for the control of high power heating appliances such 

as portable heaters. Remember to exercise good common sense when 
using the Timer features of your Remote – especially when scheduling 
unattended devices. There can be some unexpected consequences if 
not used with care. For example, an empty coffee pot can be remotely 
turned on. If that should happen, your coffee pot could be damaged from 
overheating. If an electric heater is turned on by remote control while 
clothing is draped over it, a fire could result. 

DO NOT USE

 the remote for 

the control of high power heating appliances such as portable heaters.

• Receptacle 

ON/OFF 

• Scene 

Capable

• ON/OFF 

LED

•  Two way communication 
• RF 

reliability

•  Ease of installation – No new wiring
•  Compatible with other Z-Wave

®

 enabled devices

 FEATURES

 INTRODUCTION

Testing your Receptacle prior to mounting in 
wall box:

Receptacle Mounting:

TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.

•  Restore power at circuit breaker or fuse.

•  Locator light should turn ON.

 

If locator light does not turn ON, refer to the TROUBLESHOOTING 
section.

 

Step 5

•  Position all wires to provide room in outlet wall box for device.
•  Partially screw in mounting screws in wall box mounting holes.
 

NOTE:

 Dress wires with a bend as shown in diagram in order to 

relieve stress when mounting device.

 

Step 6

Restore Power:

Restore power at circuit breaker or fuse.

 

Installation is complete.

 

Step 7

Neutral (Silver)

Line (Black)

Green
Ground

CONTROLLED

Push in side 
at tab to release

Line up tabs and 
press in sides one at a time 
to attach

 

Step 4

CONTROLLED

Installation may now be completed by tightening 
mounting screws into wall box. Attach wallplate.

NOTE: 

To include your dimmer into a network, contact 

Leviton’s Techline at 1-800-824-3005 or visit Leviton’s 
website at www.leviton.com.