BASIC commands
PROGRAMMING MANUAL
78
Revi
si
on 3.0
3.2.107 ERRORMASK
/i
3.2.108 ETHERNET
/i
Type
Axis parameter
Syntax
ERRORMASK
Description
The
ERRORMASK
axis parameter contains a mask value that is
AND
ed bit
by bit with the
AXISSTATUS
axis parameter on every servo cycle to deter-
mine if a motion error has occurred.
When a motion error occurs the enable switch (
WDOG
) will be turned off, the
MOTION_ERROR
parameter will have value 1 and the
ERROR_AXIS
parameter will contain the number of the first axis to have the error.
Check the
AXISVALUES
parameter for the status bit allocations. The default
setting of
ERRORMASK
is 268.
Arguments
N/A
Example
No example.
See also
AXIS
,
AXISSTATUS
,
MOTION_ERROR
,
WDOG
.
Caution
It is up to the user to define in which cases a motion error is gener-
ated. For safe operation it is strongly recommended to generate a
motion error when the Following Error has exceeded its limit in all
cases. This is done by setting bit 8 of
ERRORMASK
Type
System command
Syntax
ETHERNET(function, unit_number, parameter [,values])
Description
The command
ETHERNET
is used to read and set certain functions of Ether-
net communications. The
ETHERNET
command should be entered on the
command line with Trajexia Tools in disconnected mode via the serial port 0.
Note: You will have to cycle power to Trajexia to enable the new parameters.
Arguments
•
function
0 = Read, 1 = Write.
•
unit_number
-1.
•
parameter
0 = IP Address; 2 = Subnet Mask; 3 = MAC address; 8 = Gateway; 11 =
ARP cache (read-only).
•
values
The required parameter for a write.
Example
ETHERNET(1,-1,0,192,200,185,2)
Set the Trajexia IP address to 192.200.185.002.
See also
N/A
I52E-EN-03.book Seite 78 Freitag, 29. Juni 2007 11:55 11