Trajexia Tools interface
PROGRAMMING MANUAL
216
Revi
si
on 3.0
Digital IO status
fig. 39
This window allows the user to view the status of all the IO
channels and toggle the status of the output channels. It also
optionally allows the user to enter a description for each I/O line.
Digital inputs
: This shows the total number of input channels on
the Trajexia.
Digital outputs
: This shows the total number of output channels on
the Trajexia.
Display
: The display is divided up into banks containing 8
indicators, representing blocks of 8 inputs or outputs:
•
Input Bank (In)
These represent the status of the digital inputs. In(0) to In(15)
are the digital inputs built-in in TJ1-MC__. Additional Digital
inputs in the system are mapped automatically starting from
In(32).
•
Output Banks (Out)
These represent the status of the digital outputs. OP(8) to
OP(15) are the digital outputs built-in in TJ1-MC__. Additional
Digital outputs in the system are mapped automatically starting
from OP(32).
•
Input / Output Banks (I/O)
These represent virtual I/Os that you can use inside the
program as user flags. Setting one of those virtual outputs,
makes the corresponding virtual input to be set too. If an
indicator is grey then its corresponding input or output is off. If it
is coloured (yellow, green, orange, red, cyan or magenta) then
its corresponding input or output is on. Different colours are
used to represent different types of input and output.
Clicking on an indicator representing an output (or linked input
and output) results in that output changing state. Clicking on an
indicator representing an input has no effect.
•
Some output circuits require an external power source. In this
case the input state of internally linked I/O is not indicated
correctly if the external supply is not present because, even if
I52E-EN-03.book Seite 216 Freitag, 29. Juni 2007 11:55 11