87
STOP During
ORIGIN SEARCH
Feeding will be decelerated to a stop and the command must be reexecuted
from the position reached at the end of STOP.
STOP During
ORIGIN RETURN
Feeding stops according to the deceleration rate.
0
1
0
1
0
1
1
0
Time
ORIGIN RETURN
word n, bit 03
STOP
word n, bit 15
Pulse output
Busy flag
word n+5, bit 12
STOP executed flag
word n+5, bit 15
External Interrupt Commands