![background image](http://html1.mh-extra.com/html/omron/sysmac-c200h-asc02/sysmac-c200h-asc02_operation-manual_742429056.webp)
46
at the highest line number will be executed regardless of which interrupt is
invoked.
Program Example:
10
ON PC GOSUB 100
20
PC ON
30
GOTO
30
100
PC READ “3I2”; A, B, C
110
PRINT A, B, C
120
RETURN
PC PUT Statement
Purpose:
To write data to the PC’s ASCII Unit Data Memory Area
Format:
PC PUT <num exp>
<num exp> is a valid numeric expression between 0 and 255.
Examples: PC PUT I
PC PUT 123
Remarks:
Data is written to bits 8 through 15 of word n+3, where n is the first of the four
PC Data Memory words assigned to each ASCII Unit.
If the value of the numeric expression is not an integer, the INT function is
internally executed to round it off. If the value of the numeric expression is
negative or greater than 255, zero is written to the PC.
PC READ Statement
Purpose:
To read data from the PC
Format:
PC READ “<format>[,<format>,<format>, ...]”;
<var1>[,<var2>,]...
<format> specifies how the data will be read. For specific format
information, refer to Appendix D Formatting and Data Conver-
sion.
Examples:
PC READ “2H1, A3, I4, O2”; X, Y, A$, I, J
Remarks:
When the PC has written the data to the ASCII Unit, the PC READ statement
is executed.
If the PC has not written the data to the ASCII Unit, the ASCII Unit will wait
for the data, and the PC READ statement is not executed until the data com-
es.
If the number of data items output by the PC is greater than that specified by
the format parameters, the excess part of the output data will be ignored.
The maximum number of data items that can be transferred with one READ
statement specification is 255 in the S or A formats.
If an amount of memory greater than the actual memory area is specified by
the READ statement, a FORMAT ERROR will occur.
The PC READ statement’s formatting parameters can be assigned to a
single character variable and that variable may then be used in the PC READ
statement.
BASIC Language
Section 4-2
Summary of Contents for SYSMAC C200H-ASC02
Page 1: ...Cat No W165 E1 04 ASCII Unit SYSMAC C200H ASC02 ...
Page 2: ...C200H ASC02 ASCII Unit Operation Manual Revised September 2002 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 7: ...TABLE OF CONTENTS viii Glossary 159 Index 163 Revision History 165 ...
Page 122: ...Appendix B Specifications 115 130 35 100 5 ...