6
Right-Side DIP Switch Definitions
Pins 1, 2, and 3 are used for setting the baud rate of port 1.
Pin 4 is not used.
Pins 5, 6, and 7 are used for setting the baud rate of port 2.
Pin 8 is not used.
Right-Side DIP Switch Settings
Pin No.
Setting
5
6
7
0
0
0
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
1
Pin No.
Setting
1
2
3
0
0
0
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
1
300 BPS
600 BPS
1200 BPS
2400 BPS
4800 BPS
9600 BPS
300 BPS
600 BPS
1200 BPS
2400 BPS
4800 BPS
9600 BPS
19,200 BPS
Baud rate selection for port 1
Baud Rate
Not used (Always set these pins to OFF.)
Baud rate selection for port 2
Baud Rate
Not used (Always set these pins to OFF.)
OFF
ON
: 0
: 1
1
2
3
4
5
6
7
8
Back Panel
Section 1-2