ASCII Unit Memory Map
Appendix E
138
Devices
PTM HD63B40
Address
R/W
Contents
System Default Value
Remarks
$9800
R
0
None
W
Control registers #1 and #3
$82
Writes to #3
$9801
R
Status register
None
W
Control register #2
$00
$9802
R
Higher byte of timer #1 counter
None
W
Higher byte (MSB) of buffer register
None
$9803
R
Lower byte (LSB) of buffer register
None
W
Lower byte of timer 1 latch
None
$9804
R
Higher byte of timer #2 counter
None
W
Higher byte (MSB) of buffer register
None
$9805
R
Lower byte (LSB) of buffer register
None
W
Lower byte of timer #2 latch
None
$9806
R
Higher byte of timer #3 counter
None
W
Higher byte (MSB) of buffer register
None
Changes depend on
transfer rate
$9807
R
Lower byte (LSB) of buffer register
None
W
Lower byte of timer #3 latch
None
RTC-62461 Real-Time Clock
Address
R/W
Contents
System Default Value
$9000
R/W
1-second digit: 0-9
None
$9001
R/W
10-second digit: 0-5
None
$9002
R/W
1-minute digit: 0-9
None
$9003
R/W
10-minute digit: 0-5
None
$9004
R/W
1-hour digit: 0-9
None
$9005
R/W
10-hour digit: 0-2
None
$9006
R/W
1-day digit: 0-9
None
$9007
R/W
10-day digit: 0-3
None
$9008
R/W
1-month digit: 0-9
None
$9009
R/W
10-month digit: 0-1
None
$900A
R/W
1-year digit: 0-9
None
$900B
R/W
10-year digit: 0-9
None
$900C
R/W
Week digit: 0-6
None
$900D
R/W
Control register D
0 is set in D0.
$900E
R/W
Control register E
None
$900F
R/W
Control register F
0 is set in D0, 1, and 3.
Summary of Contents for SYSMAC C200H-ASC02
Page 1: ...Cat No W165 E1 04 ASCII Unit SYSMAC C200H ASC02 ...
Page 2: ...C200H ASC02 ASCII Unit Operation Manual Revised September 2002 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 7: ...TABLE OF CONTENTS viii Glossary 159 Index 163 Revision History 165 ...
Page 122: ...Appendix B Specifications 115 130 35 100 5 ...
Page 168: ...Cat No W165 E1 04 C200H ASC02 ASCII Unit OPERATION MANUAL ...