SQ Remote Power Management                                                                                                                User’s Manual 

 
 

 

User's Manual 

 

For 

SP/NP Series Remote Power Management

 

 

SP/NP 02, SP/NP 08, SP/NP 16 and SP/NP 20 

 
 

V1.1 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Shanghai Qianjin Electronic Equipment Co.,Ltd 

 
 
 

____________________________________________________________

Addr

A/4F, 2# Building , No.401, Caobao Road , Shanghai ,China            Zip

200233        Web

www.sq-catv.com

   

 Fax

86-21-64858301 - 62401979      Tel

86-21-54973555 – 34140103 - 64957666     E-mail

[email protected]

 

Summary of Contents for SP 02

Page 1: ...SP NP 16 and SP NP 20 V1 1 Shanghai Qianjin Electronic Equipment Co Ltd ____________________________________________________________1 Addr A 4F 2 Building No 401 Caobao Road Shanghai China Zip 200233...

Page 2: ...vices has been tested and shown to comply with the following FCC rule Part 15 Subpart Jand ICES 003 FCC Declaration Compliance 47CFR Part 15 regulation ANSI C63 4 Class B CE Safety Standards Complianc...

Page 3: ...13 3 2 User Privileges and Port Reservations 14 3 3 Local Master Port Access 14 3 4 External Modem Access 14 3 5 Telnet Access 15 3 6 WEB Access 16 3 7 Email Access 17 3 8 SNMP Information 18 3 9 Aut...

Page 4: ...8 NP SP 16R Back Panel Illustration 9 Figure 9 NP SP 20U Front Panel Illustration 10 Figure 10 System Startup Screen 13 Figure 11 Telnet Session Startup screen 15 Figure 12 Web Access Startup Page NP...

Page 5: ...00 240 VAC 100 240 VAC 100 240 VAC 100 240 VAC W 6 0 150mm W 19 482mm W 19 482mm W 2 0 50mm D 6 7 170mm D 7 0 180mm D 7 180mm D 2 75 70mm Chassis H 1 75 44mm H 1 75 44mm H 3 5 88mm H 55 1400mm Console...

Page 6: ...0VAC 2 ea 20 Amp 20 Amps 40 Amps NP SP 16E 16 100 240VAC 2 ea 16 Amp 16 Amps 32 Amps NP SP 16U 16 100 120VAC 2 ea 15 Amp 15 Amps 30 Amps NP SP 20R 20 100 120VAC 1 2 ea 20 Amp 20 Amps 40 Amps NP SP 20E...

Page 7: ...exchange of management information between the system and network devices POP SMTP Emailing with SMTP Authentication capability A user can send control commands such as reboot power outlet via emails...

Page 8: ...oted Scheduling AC outlet power cycling periodically or per weekly planner Each outlet can be programmed with it s own timer Figure 2 Illustration of Typical Application 1 3 Front and Back Panel Figur...

Page 9: ...Figure 7 NP SP 16R E U Front Panel Illustration ____________________________________________________________9 Addr A 4F 2 Building No 401 Caobao Road Shanghai China Zip 200233 Web www sq catv com Fax...

Page 10: ...ection Temperature Indicators When the LED is illuminated Temperature which measurement will appear on the Digital Displays 11 Display Selection Button Each time the Display Selection Button is presse...

Page 11: ...booted in response 24 Power Circuit B Switched Outlets AC Outlets that can be switched On Off or rebooted in response Caution Sensor interface can be connected only with the sensor provided by the man...

Page 12: ...d service personnel only The unit should be installed in indoor with ambient temperature and sufficient airflow WARNING Ensure that the hardware you are working with is disconnected from the power sup...

Page 13: ...There are two ways to restore the system to the Factory Default settings The first method is to press a push button switch located on the front panel for 1 second The second method is to select Set De...

Page 14: ...em configuration settings and operate unreserved power outlets 3 3 Local Master Port Access To access and configure the system from the master port you need to connect a RS232 port from your work stat...

Page 15: ...r telnet ip_addr The telnet terminal screen will display the following message once it starts shown in Figure 8 You need to set a Telnet session on your workstation to Local Echo Off mode Telnet sessi...

Page 16: ...p_address for SP serial in the address field You must have an account on the system in order to access the system via this method Without a valid account you are only able to view the following web pa...

Page 17: ...ncoming mails from a designated POP mail server The system sends a reply email with command process status if an email is intercepted See Section 4 4 for more information about how to setup email acco...

Page 18: ...text file describing the internal objects the SNMP agent can display monitor and or modify Each MIB object is the system variable that has name and an OID as shown in Figure 12 You need the MIB file t...

Page 19: ...network connection is not detected any more However user equipment never gets power reboot if the equipment never replies ping reply to a NP system A power outlet has the optional settings Power Outle...

Page 20: ...lnet session Some of the control commands are also applicable to emails See related sections for more detailed information about how to setup email accounts Once the system starts or a Telnet session...

Page 21: ...outlet n for current user mac print the mac addr ping 10 10 26 236 ping an ip address acl 0 1 Disable Enable ACL aclset id type mask id 1 6 type 0 Not Care 1 Permit 2 Block mask ip smtp lalalalala se...

Page 22: ...5 2 Viewing and Changing Operation Status Figure 14 shows a web page that lets you to view and change power outlet operation status Figure 17 System Operation Static Web Page With this web page you a...

Page 23: ...r off state Reservation Reserve the port for special user AutoPing and reboot Power reboot If user equipment s network is down Disable or enable AutoPing power reboot function If it is enabled the sys...

Page 24: ...when autping failed or clicking Reboot push switch button icon The uint is second Helpful Info Use command pshow to display all power outlet status Power Outlet Port Parameters and Status Port Name st...

Page 25: ...ntry data is 08 07 20 19 17 27 Timer Period Specify the timer period It is in the format of days hours minutes seconds which is not a calendar and real time clock entry type The period setting is used...

Page 26: ...tlet will toggle on off state for 10 seconds Timer Loop Count 1000 1000 days 2 Toggle Power Outlets for 300 times Toggling Power outlet on off state 300 times in a period of 10 seconds starts immediat...

Page 27: ...ing new user accounts modifying and deleting user accounts Figure 22 User Account Management Menu Web Page Helpful Info Use the command ul to view all existing account ________________________________...

Page 28: ...onnector Since the system s Local Master Port and Modem device ports are not complementary you need to use a NULL Modem cable with both male connectors For information about connecter pin assignment p...

Page 29: ...up email accounts Default to disable SNMP Agent Enabling Enable or disable SNMP agent on the system If the system SNMP Agent is enabled it collects and stores management information and makes this inf...

Page 30: ...ess is used for exchanging data between the system s Ethernet interface port and user communication equipment without enabling flow control you might experience data loss when data exchange rate is hi...

Page 31: ...or a network device on a network There must be a DHCP server on a network running and the server must permit an assigned computer or network device to be on the LAN If this option is disabled the syst...

Page 32: ...entry is for your IP network class which is distinguished by using a subnet mask Gateway IP address Specifies a gateway IP address that is a part of your static network address settings This is your r...

Page 33: ...nd alarm report Also the system always send replying email to the sender There is no limitation of types of destination email servers whether a web based emailing system or SMTP Examples of destinatio...

Page 34: ...network Obtain IP using DHCP Get IP by DHCP Helpful Info use the command ifconfig dhcp to perform this function Fallback to static IP if DHCP failed Define a static IP address If DHCP failed allow the...

Page 35: ...e sending email subject rcs and content admin admin help will get all email supporting command The user name is admin and password is admin Figure 11 shows an example of sending a control command emai...

Page 36: ...oblem with as much detail as possible Purchaser may be required to perform certain diagnostics tests on Product prior to SQ issuing an RMA SQ at its discretion may use new refurbished or reconditioned...

Page 37: ...ny special incidental or consequential damages caused or alleged to be caused directly or indirectly by Product or those items supplied or sold by SQ hereunder including but not limited to any interru...

Page 38: ...sole Port Interfaces ____________________________________________________________38 Addr A 4F 2 Building No 401 Caobao Road Shanghai China Zip 200233 Web www sq catv com Fax 86 21 64858301 62401979 Te...

Page 39: ...4858301 62401979 Tel 86 21 54973555 34140103 64957666 E mail sqjeecl online sh cn History Revision Author Date Comments V1 0 liudm 2010 1 14 Add default IP address settings SP NP type and this revisio...