5-2
5-1
Protective and Diagnostic Functions
The 3G3EV has excellent protective and diagnostic functions. The RUN
and ALARM indicators on the front panel indicate the current Inverter sta-
tus, and the data display section also displays information about an error
that has occurred. These functions therefore enable the user to take the
appropriate actions to correct most errors.
H
List of Error Codes
Inverter
Indicator
Data
Description
status
RUN
ALARM
display
Normal
Flashes
Not lit
---
Ready to run
Lit
Not lit
---
Normal operation in progress
Warning
Flashes
Flashes
ef
Simultaneous input of forward and re-
verse rotation commands
Lit
Flashes
uU
Main circuit undervoltage (UV)
%U
Main circuit overvoltage (OV)
%h
Radiation fin overheated (OH)
Digital Operator stopped (STP)
Protective
Not lit
Lit
%c
Overcurrent (OC)
mecha-
%U
Main circuit overvoltage (OV)
nism actu-
uU1
Main circuit undervoltage (UV1)
ated
uU2
Control power supply fault (UV2)
%h
Radiation fin overheated (OH)
%l1
Motor overload (OL1)
%l2
Inverter overload (OL2)
ef1
External fault (EF1)
Inverter
Not lit
Lit
f00
Initial memory error
error
f01
ROM error
f04
Constant error
f05
A/D converter error
f06
Option error
Not lit
Not lit
(Not lit)
Control circuit error
Operation
Chapter 5
Summary of Contents for SYSDRIVE 3G3EV SERIES
Page 1: ...USER S MANUAL SYSDRIVE 3G3EV Standard Models Compact Low noise Inverter Cat No I011 E1 3...
Page 5: ...Chapter 1 Getting Started 1 1 Items to be Checked when Unpacking 1 2 Precautions 1...
Page 9: ...Chapter 2 Overview 2 1 Features 2 2 Component Names 2...
Page 14: ...Chapter 3 Design 3 1 Installation 3 2 Wiring 3...
Page 72: ...Chapter 6 Specifications 6 1 Specifications of Main Unit 6...