40
Muting Controller RM-6
Section 12-1
The MS4800 system requires a specific sequence to activate the muting func-
tion after the RM-6 is connected to the receiver. Once the RM-6 is connected
the system will not operate until either the mute module is removed or the fol-
lowing sequence is followed:
• The MS4800 will fault "71", (mute module enable and configuration
required)
1.
Turn ON the power supply of the MS4800 system and the RM6, the start
button must be pressed for app. 3 seconds until all status LEDs of the re-
ceiver SLC are flashing shortly.
2.
Release the start button while the status LEDs are flashing
3.
The MS4800 system performs a system reboot. When this sequence is
properly completed, muting function is enabled.
The status LED of the receiver turns to green and the status LED of the RM6
lights permanently.
When this sequence is properly completed, the system will enable muting.
For further information please check the user manual of the MS4800-RM6.
Summary of Contents for MS4800E
Page 2: ......
Page 4: ...iv...
Page 6: ...vi...
Page 20: ...2 Section...
Page 26: ...8 MS4800FS Cascaded Series Section 4 3...
Page 34: ...16 Optical Synchronization Section 5 4...
Page 40: ...22 Selecting Scan Codes Section 7 7...
Page 42: ...24 Auxiliary Output Section 8 2...
Page 52: ...34 General Mounting Considerations Section 10 3...
Page 56: ...38 Connection to a safety relay unit Section 11 3...
Page 60: ...42 Using the test object Section 13 3...
Page 62: ...44 Section...
Page 88: ...70 Accessories Section 15 9...
Page 90: ...72 Section...
Page 97: ...79 EC Declaration of Conformity Section 18 3 18 3 EC Declaration of Conformity...