28
Safety distance and beam heights in access guarding
Section 9-3
9-3
Safety distance and beam heights in access guarding
!WARNING
Additional countermeasures may be necessary to prevent access to the dan-
gerous area from above, below, the sides or the rear of the machine.
According to EN999 and EN294:
The height of the protective field "H" above the reference plane and the reso-
lution "d" of the MS4800 system have the following relationship:
S =
(K x T) + C
For K and T please refer to the previous chapter
C =
8 x (d - 14)
d = resolution of the MS4800 system
S =
(2000 mm x T) + 8 x (d - 14)
H
S
L
Direction of
approach
Resolution
Lowest beam above
reference plane
Highest beam above
reference plane
Additional
amount C
(see formula)
14 mm
In accordance with
EN 294
In accordance with
EN 294
0 mm
30 mm
In accordance with
EN 294
In accordance with
EN 294
128 mm