47
System Specification
Section 15-1
Response time of MS4800 system
One segment system
Two segment system
Minimum
number of
beams
Maximum
number of
beams
Response
Time
Minimum
number of
beams
Maximum
number of
beams
Response
Time
0
16
14 ms
0
65
23 ms
17
71
23 ms
66
120
32 ms
72
126
32 ms
121
174
41 ms
127
180
41 ms
175
229
50 ms
181
235
50 ms
230
256
59 ms
236
256
59 ms
Three segment system
Four segment system
Minimum
number of
beams
Maximum
number of
beams
Response
Time
Minimum
number of
beams
Maximum
number of
beams
Response
Time
0
59
23 ms
0
53
23 ms
60
114
32 ms
54
108
32 ms
115
168
41 ms
109
162
41 ms
169
223
50 ms
163
217
50 ms
224
256
59 ms
218
256
59 ms
Conformity
AOPD(ESPE)
Type 4 acc. to EN/IEC 61496-1 (2004)
And EN/IEC 61496-2 (2006)
Safety category
MS4800E system is suitable for safety control systems
up to Category 4 acc. EN954-1 (1996)
Safety Integrity Level
MS4800E system is suitable for up to SIL 3 per
IEC 61508
PFH
3,5 * 10
-08
Proof test interval
Every 2 years (based on max. number of channels in a
4 segment system including muting system).
Summary of Contents for MS4800E
Page 2: ......
Page 4: ...iv...
Page 6: ...vi...
Page 20: ...2 Section...
Page 26: ...8 MS4800FS Cascaded Series Section 4 3...
Page 34: ...16 Optical Synchronization Section 5 4...
Page 40: ...22 Selecting Scan Codes Section 7 7...
Page 42: ...24 Auxiliary Output Section 8 2...
Page 52: ...34 General Mounting Considerations Section 10 3...
Page 56: ...38 Connection to a safety relay unit Section 11 3...
Page 60: ...42 Using the test object Section 13 3...
Page 62: ...44 Section...
Page 88: ...70 Accessories Section 15 9...
Page 90: ...72 Section...
Page 97: ...79 EC Declaration of Conformity Section 18 3 18 3 EC Declaration of Conformity...