46
System Specification
Section 15-1
Electrical
Power Input Transmitter
24 VDC ±20%, maximum current 285 mA
MTS Input
24 VDC ±20%, 20 mA typ.
Power Input Receiver
24 VDC ±20%, maximum current 1835 mA
Receiver 485 mA + AUX 100 mA +
OSSD1 625 mA + OSSD2 625 mA
Leakage current
< 1mA
Capacitive Load
< 4.7µF for OSSD output
Inductive Load
Please contact your Omron representative for further
information.
Test pulse data
t1: Test pulse
≤
600 µs
t2: 4 ms
≤
Test interval
≤
40 ms
t3: Repetition
≤
5 min
Muting Option
24 VDC ±20%, 30 mA max.
Muting Duration
Approx. 2 min. or No time limit
Power Supply
Must meet the requirements of EN/IEC 60204-1 and
EN/IEC 61496-1, and must guarantee safe insulation
from the mains voltage in accordance with IEC 60742
and be able to cover a drop of supply voltage of at least
20 ms.
Protection class
(IEC 536 or VDE 106)
III
Environmental
Enclosure Rating
IP65
Operating Temperature
-10°C … +55°C
Storage Temperature
-25°C … +70°C
Relative Humidity
95% maximum, non-condensing
Vibration (IEC 60068-2-6)
10 - 55 Hz, 10g, maximum on all 3 axes
Shock (IEC 60086-2-29)
10g for 16 ms, 1000 shocks on all 3axes
Connections
Cable length
MS4800 Transmitter
Unshielded cables:
Max. 50 m, @ 0.32 mm²
We recommend to use the F39-JMT cables or as
alternative the F39-TGR-CVL-B-_E (shielded) to
connect the MS4800 system to the machine control
system.
Cable length
MS4800 Receiver
Unshielded cables, length is depending on the maxi-
mum current consumption:
OSSD 1&2-load 625 mA: 12 m @ 0.5 mm²
OSSD 1&2-load 300 mA: 45 m @ 0.5 mm²
We recommend to use the F39-JMR cables or as
alternative the F39-TGR-CVL-B-_R (shielded) to
connect the MS4800 system to the machine control
system.
Cable length
MS4800FS system
Shielded cables, M12 connector 4-pin, these cables are
available as accessories. Maximum length is 10 m
between segments
OSSD 1
OSSD 2
t
1
t
2
t
3
t
Summary of Contents for MS4800E
Page 2: ......
Page 4: ...iv...
Page 6: ...vi...
Page 20: ...2 Section...
Page 26: ...8 MS4800FS Cascaded Series Section 4 3...
Page 34: ...16 Optical Synchronization Section 5 4...
Page 40: ...22 Selecting Scan Codes Section 7 7...
Page 42: ...24 Auxiliary Output Section 8 2...
Page 52: ...34 General Mounting Considerations Section 10 3...
Page 56: ...38 Connection to a safety relay unit Section 11 3...
Page 60: ...42 Using the test object Section 13 3...
Page 62: ...44 Section...
Page 88: ...70 Accessories Section 15 9...
Page 90: ...72 Section...
Page 97: ...79 EC Declaration of Conformity Section 18 3 18 3 EC Declaration of Conformity...