SIM-05 

SHOCK AND GLASS 

BREAKE DETECTOR 

 

 
 
 
 

 
 

 

 
 
 
 

 

INSTALLATION INSTRUCTIONS 

P/N 7107527 Rev A 

DETECTOR PATTERN COVERAGE 

 

 

 

The detector offers flexible installation. It 
can be either ceiling mounted or wall 
mounted as shown in the figure above.

 

 

  If heavy blinds or curtains cover the glass, you 

must locate the detector behind the blinds on 
the window frame or above it, otherwise the 
blinds might block the sound. Make sure to 
test the unit thoroughly for proper detection. 

  Install the detector in a direct line of sight with 

the protected glass. 

  Do not mount the unit in front of air ducts, or 

close to bells (measuring 0.5m (or larger) in 
diameter).

 

  For a few protected glasses in one room, 

locate the detector in optimal distance from 
them to achieve the best detection.

 

 

 

 

SPECIFICATION 

 
Sensor                              Microphone 
                                          Electro Condenser 
 
Power Input

                            

9 - 16 Vdc 

 
Current Consumption

       

Standby: 22mA at 12Vdc 

                                        Active: 25mA at 12Vdc 
 
Detection Range

              

10m, Adjustable 

 
Mounting

                              

Ceiling or Wall 

 
Alarm Output Relay

          

N.C 50mA/24Vdc with 

                                       27 Ohm in line resistor 

 
Tamper Switch

                   

N.C 50mA  24Vdc with 

                                        10 Ohm in line resistor 
 
Operating Temperature    -20

C to 50

 
Operating Humidity           95% max relative  
Range                               non condensing 
 
Storage Temperature       -30

C to 70

 
RFI Protection                   30V/m  10 -1000MHz 
 
EMI Protection                   50,000V electrical   

                                         Interference from 
                                         lightning 

 

Dimensions

                             

78mm x 51mm x 21mm 

 
 

 

INSTALLING THE DETECTOR 

 

PCB LAYOUT 

 
 

 

 

1.

  Use a small screwdriver to push the 

prong on top of the case and open the 
case. 

2.

  Snap out the detector PCB.  

3.

  Insert the wires through the wiring 

hole (B). 

4.

  Use the mounting holes (A) to mount 

the detector. 

5.

  Connect the wires to the 

terminal.(See Terminal Connections) 

6.

  Reinstall the detector PCB. 

7.

  Close the case. 

 
 

JUMPERS ( FIG. 4 ) 

 

JP1

 - Shock / Glass selector for 

detection calibration. 

 

JP2

 - Memory LED control. 

 

JP3

 - Reduces the sensitivity of 

sound detection by 50%. 

 

 

 

WIRE REQUIREMENTS

 

 

Use #22 AWG (0.5mm) or wires with a larger 
diameter. Use the following table to determine 
required wire gauge (diameter) and length of wire 
between the detector and the control panel. 

 

Wire Length       m     200    300    400     800 

Wire Diameter  mm    .5      .75      1.0     1.5 

Wire Length       ft      800   1200  2000   3400 

Wire Gauge       #       22      20      18       16 
 

 

 
 