K8DT-TH

9

Safety Precautions

Be sure to read the precautions for all models in the website at the following URL: http://www.ia.omron.com/.

Warning Indications

Meaning of Product Safety Symbols

 

!

CAUTION

Doing so may occasionally result in minor injury due 
to electric shock. Do not touch the Relay while the 
power supply is ON, except for the adjustment knob 
and buttons.

There is a risk of minor electrical shock, fire, or device 
failure. Do not allow any pieces of metal, conductors, or 
cutting chips that occur during the installation process to 
enter the product.

Explosions may cause minor injuries. Do not use the 
product in locations with inflammable or explosive 
gases.

There is a risk of minor electrical shock, fire, or device 
failure. Do not disassemble, modify, repair, or touch 
the inside of the product.

If the setting does not match the element to be 
controlled, the product may behave unexpectedly and 
damage the machine or cause accidents. Set the 
Temperature Monitoring Relay as described below.

• Make sure that all parameters are set suitably for the monitor 

targets.

• Make sure that the power supply is turned OFF before you change 

any DIP switch setting. The DIP switch settings take effect when 
the power is turned ON.

If the Relay fails, monitoring and alarm outputs may 
fail to operate. This may result in physical damage to 
the facilities, equipment, or other devices that are 
connected to it. To reduce this risk, inspect the Relay 
regularly. To maintain safety in the event of 
malfunction of the Relay, take appropriate safety 
measures, such as installing a monitoring device on a 
separate line.

Use of the product beyond its life may result in 
contact welding or burning. Make sure to consider the 
actual operating conditions and use the product 
within its rated load and electrical life count. The life 
of the output relay varies significantly with the switching 
capacity and switching conditions.

If the Relay is used with incorrect wiring, fire may 
occasionally occur, possibly resulting in physical 
damage. Check the wiring for mistakes before you 
turn ON the power supply.

If the wire insertion length is insufficient, fire may 
occasionally occur, possibly resulting in physical 
damage. Insert the wires all the way to the back.

The terminal block may be damaged if you insert a 
flat-blade screwdriver in the release hole with 
excessive force. Insert the flat-blade screwdriver into 
the release holes with a force of 15 N or less.

 CAUTION

Indicates a potentially hazardous 

situation which, if not avoided, may result 

in minor or moderate injury or in property 

damage.

Precautions for 

Safe Use

Supplementary comments on what to do 

or avoid doing, to use the product safely.

Precautions for 

Correct Use

Supplementary comments on what to do 

or avoid doing, to prevent failure to 

operate, malfunction, or undesirable 

effects on product performance.

Used to warn of the risk of electric shock under 

specific conditions.

Used for general prohibitions for which there is 

no specific symbol.

Used to indicate prohibition when there is a risk 

of minor injury from electrical shock or other 

source if the product is disassembled.

Used for general mandatory action precautions 

for which there is no specified symbol.

Summary of Contents for K8DT-TH

Page 1: ...Models added with transistor outputs for superior contact reliability Ordering Information Temperature Input Models Refer to Setting Ranges on page 3 for the setting ranges Options Order Separately Fr...

Page 2: ...length 8 mm Ferrule length 8 mm Recommended flat blade screwdriver XW4Z 00B Omron SZF 0 4 2 5 Phoenix Contact 210 719 Wago SDI 0 4 2 5 75 Weidmuller Current capacity 10 A per pole Number of insertions...

Page 3: ...0 400 100 0 0 0 0 0 0 0 Minimum setting increment 10 C Input K J T E B R S PL II Setting temperature range 3 200 3 100 3 000 2 900 2 800 2 700 2 600 2 500 2 400 2 300 2 200 2 100 2 000 1 900 1 800 1 7...

Page 4: ...DIP SW Inside Inside 2 Output C Relay Output T Transistor Output 14 11 12 14 11 3 Power supply voltage A 100 to 240 VAC D 24 VAC VDC No polarity A1 A2 A1 A2 Relay output normally closed 11 to 14 Relay...

Page 5: ...not resume normal operation it must be replaced Latching and the SV Protect Mode are stored in non volatile memory An error may occur if the data is updated more than one million times If you press a...

Page 6: ...11 Sinking In the case of sinking output applications 14 load K8DT 11 In the case of sourcing output applications 14 Sourcing O N 1 2 3 4 5 6 7 8 SW3 DIP Switch SW2 SW1 SW4 SW7 SW6 SW5 SW8 Turn OFF th...

Page 7: ...g Without latching Output drive method Normally open Normally closed Temperature unit C F Input type K J T E Pt100 Pt1000 NOT USE NOT USE R_SW3 1 000 C F units 0 to 3 Note A temperature setting error...

Page 8: ...17 5 90 86 90 5 100 Temperature Monitoring Relay K8DT TH Options Order Separately Front Cover Y92A D1A 52 7 3 5 1 8 17 5 5 85 DIN Tracks PFP 100N PFP 50N Dimensions in parentheses are for the PFP 50N...

Page 9: ...lay take appropriate safety measures such as installing a monitoring device on a separate line Use of the product beyond its life may result in contact welding or burning Make sure to consider the act...

Page 10: ...ndustrial waste 21 Make sure the indicators operate correctly Depending on the application environment the indicators may deteriorate prematurely and become difficult to see 22 The maximum terminal te...

Page 11: ...at it will not come off and the wire is securely fastened to the terminal block If you use a ferrule with a conductor length of 10 mm part of the conductor may be visible after the ferrule is inserted...

Page 12: ...ulation between the power supply terminals and input terminals There is basic insulation between the power supply terminals and output terminals There is basic insulation between the input terminals a...

Page 13: ...CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Pr...

Page 14: ...9 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Kyo...

Page 15: ...0HZ GCA32A240VAC50 60HZ GCA32A48VAC60HZ GCA63A120VAC50 60HZ GCA63A208VAC60HZ GCA63A220VAC60HZ GCA63A230VAC50 60HZ GCA63A240VAC50 60HZ GCA63A277VAC60HZ GCA63A48VAC60HZ GCA63A500VAC50 60HZ GCA63A600VAC6...

Reviews: