background image

Terms and Conditions Agreement

Read and understand this catalog.

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have 
any questions or comments. 

Warranties.

(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship 

for a period of twelve months from the date of sale by Omron (or such other period expressed in writing 
by Omron). Omron disclaims all other warranties, express or implied.

(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT 

NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE 
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL 
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.

Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products 
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, 
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the 
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price 
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other 
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, 
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by 
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or 
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system 
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in 
writing, are not to be construed as an amendment or addition to the above warranty.

See http://www.omron.com/global/ or contact your Omron representative for published information.

Limitation on Liability; Etc.

OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, 
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, 
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.

Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.

Suitability of Use.

Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the 
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable 
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is 
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, 
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with 
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. 

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE 
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE 
OVERALL EQUIPMENT OR SYSTEM.

Programmable Products.

Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.

Performance Data.

Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining 
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it 
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.

Change in Specifications.

Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice 
to change part numbers when published ratings or features are changed, or when significant construction changes are made. 
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be 
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to 
confirm actual specifications of purchased Product.

Errors and Omissions.

Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is 
assumed for clerical, typographical or proofreading errors or omissions.

Summary of Contents for K8DT-TH

Page 1: ...Models added with transistor outputs for superior contact reliability Ordering Information Temperature Input Models Refer to Setting Ranges on page 3 for the setting ranges Options Order Separately Fr...

Page 2: ...length 8 mm Ferrule length 8 mm Recommended flat blade screwdriver XW4Z 00B Omron SZF 0 4 2 5 Phoenix Contact 210 719 Wago SDI 0 4 2 5 75 Weidmuller Current capacity 10 A per pole Number of insertions...

Page 3: ...0 400 100 0 0 0 0 0 0 0 Minimum setting increment 10 C Input K J T E B R S PL II Setting temperature range 3 200 3 100 3 000 2 900 2 800 2 700 2 600 2 500 2 400 2 300 2 200 2 100 2 000 1 900 1 800 1 7...

Page 4: ...DIP SW Inside Inside 2 Output C Relay Output T Transistor Output 14 11 12 14 11 3 Power supply voltage A 100 to 240 VAC D 24 VAC VDC No polarity A1 A2 A1 A2 Relay output normally closed 11 to 14 Relay...

Page 5: ...not resume normal operation it must be replaced Latching and the SV Protect Mode are stored in non volatile memory An error may occur if the data is updated more than one million times If you press a...

Page 6: ...11 Sinking In the case of sinking output applications 14 load K8DT 11 In the case of sourcing output applications 14 Sourcing O N 1 2 3 4 5 6 7 8 SW3 DIP Switch SW2 SW1 SW4 SW7 SW6 SW5 SW8 Turn OFF th...

Page 7: ...g Without latching Output drive method Normally open Normally closed Temperature unit C F Input type K J T E Pt100 Pt1000 NOT USE NOT USE R_SW3 1 000 C F units 0 to 3 Note A temperature setting error...

Page 8: ...17 5 90 86 90 5 100 Temperature Monitoring Relay K8DT TH Options Order Separately Front Cover Y92A D1A 52 7 3 5 1 8 17 5 5 85 DIN Tracks PFP 100N PFP 50N Dimensions in parentheses are for the PFP 50N...

Page 9: ...lay take appropriate safety measures such as installing a monitoring device on a separate line Use of the product beyond its life may result in contact welding or burning Make sure to consider the act...

Page 10: ...ndustrial waste 21 Make sure the indicators operate correctly Depending on the application environment the indicators may deteriorate prematurely and become difficult to see 22 The maximum terminal te...

Page 11: ...at it will not come off and the wire is securely fastened to the terminal block If you use a ferrule with a conductor length of 10 mm part of the conductor may be visible after the ferrule is inserted...

Page 12: ...ulation between the power supply terminals and input terminals There is basic insulation between the power supply terminals and output terminals There is basic insulation between the input terminals a...

Page 13: ...CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Pr...

Page 14: ...9 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Kyo...

Page 15: ...0HZ GCA32A240VAC50 60HZ GCA32A48VAC60HZ GCA63A120VAC50 60HZ GCA63A208VAC60HZ GCA63A220VAC60HZ GCA63A230VAC50 60HZ GCA63A240VAC50 60HZ GCA63A277VAC60HZ GCA63A48VAC60HZ GCA63A500VAC50 60HZ GCA63A600VAC6...

Reviews: