Single-phase Current Relay

 K8AB-AS

3

Ratings

Note:

Models with a 24-VDC power supply have a non-isolated power supply; the inputs and power supply are connected internally. If both the 
input and power supply are grounded, an unwanted current path will be created and the Unit will not operate normally.
If an unwanted current path exists, use a K8AB model with an AC power supply or use an isolated DC power supply.

Power supply 
voltage

Non-isolated power supply

24 VDC (See note.)

Isolated power supply

24 VAC, 100 to 115 VAC, 200 to 230 VAC

Power consumption

24 VDC: 

1 W max.

24 VAC: 

4 VA max.

100 to 115 VAC: 4 VA max.
200 to 230 VAC: 5 VA max.

Operating value setting range (SV)

10% to 100% of maximum measuring current
K8AB-AS1: 2 to 20 mA AC/DC

10 to 100 mA AC/DC
50 to 500 mA AC/DC

K8AB-AS2: 0.1 to 1 A AC/DC

0.5 to 5 A AC/DC
0.8 to 8 A AC/DC

K8AB-AS3: When used together with a K8AC-CT200L Current Transformer

10 to 100 A AC
20 to 200 A AC

Operating value

100% operation at set value

Reset value setting range (HYS.)

5% to 50% of operating value

Reset method

Manual reset/automatic reset (switchable)

Note:

 Manual reset: Turn OFF power supply for 1 s or longer.

Operating time setting range (T)

0.1 to 30 s

Startup lock time setting range (LOCK)
Note:

 Enabled only for overcurrent operation.

0 to 30 s
(The startup lock timer starts when the input has reached approximately 30% or more of the set value.)

Note:

 Enabled only for overcurrent operation.

Indicators

Power (PWR): Green, Relay output (RY): Yellow, Alarm outputs (ALM): Red

Input impedance

Refer to th

“Input Range”

 on the previous page.

Output relays

One SPDT relay (NO/NC switched using DIP switch.)

Output relay ratings

Rated load

Resistive load
6 A at 250 VAC (cos

φ

 = 1)

6 A at 30 VDC (L/R = 0 ms)
Inductive load
1 A at 250 VAC (cos

φ

 = 0.4)

1 A at 30 VDC (L/R = 7 ms)

Maximum contact voltage: 

250 VAC

Maximum contact current: 

6 A AC

Maximum switching capacity:  1,500 VA
Minimum load: 

10 mA at 5 VDC

Mechanical life: 

10,000,000 operations

Electrical life:

Make: 50,000 times, Break: 30,000 times

Ambient operating temperature

20 to 60°C (with no condensation or icing)

Storage temperature

40 to 70°C (with no condensation or icing)

Ambient operating humidity

25% to 85% (with no condensation)

Storage humidity

25% to 85% (with no condensation)

Altitude

2,000 m max.

Terminal screw tightening torque

0.49 N·m

Terminal wiring method

Recommended wire

Solid wire: 

2.5 mm

2

Twisted wires:  AWG16, AWG18

Note: 1.

Ferrules with insulating sleeves must be used with twisted wires.

2.

Two wires can be twisted together.

Recommended ferrules

Al 1,5-8BK (for AWG16) manufactured by Phoenix Contact
Al 1-8RD (for AWG18) manufactured by Phoenix Contact
Al 0,75-8GY (for AWG18) manufactured by Phoenix Contact

Case color

Munsell 5Y8/1

Case material

ABS resin (self-extinguishing resin) UL94-V0

Weight

DC models: Approx. 110 g
AC models: Approx. 150 g

Mounting

Mounted to DIN Track or via M4 screws (tightening torque: 1.2 N·m)

Dimensions

22.5 (W) 

×

 90 (H) 

×

 100 (D) mm

Summary of Contents for K8AB-AS

Page 1: ...Commercial CT input signal 0 to 1 A 0 to 5 A supported Output status can be monitored using LED indicator Model Number Structure Model Number Legend 1 Basic Model K8AB Measuring and Monitoring Relays...

Page 2: ...1 to 1 A AC DC 0 5 to 5 A AC DC 0 8 to 8 A AC DC 24 VDC not insulated K8AB AS2 24 VDC See note 1 24 VAC insulated K8AB AS2 24 VAC 100 115 VAC insulated K8AB AS2 100 115 VAC 200 230 VAC insulated K8AB...

Page 3: ...ely 30 or more of the set value Note Enabled only for overcurrent operation Indicators Power PWR Green Relay output RY Yellow Alarm outputs ALM Red Input impedance Refer to the Input Range on the prev...

Page 4: ...luence Operating value Based on ambient humidity of 65 25 to 80 5 max Operating time Based on ambient room humidity 25 to 80 10 max Influence of power supply voltage Operating value 5 max Operating ti...

Page 5: ...current path if the inputs and power supply are connected to the same line T LOCK Hysteresis 5 to 50 of operating value Lit Flashing T Operating time 0 1 to 30 s Lock Startup lock time 0 to 30 s Oper...

Page 6: ...K Alarm indicator Terminal block See notes 1 and 2 Terminal block See notes 1 and 2 Item Meaning Power indicator PWR Green Lit when power is being supplied Relay status indicator RY Yellow Lit when re...

Page 7: ...method relay drive method and operating mode are set using the DIP switch located on the bottom of the Unit K8AB AS does not use SW1 Setting Method 1 Setting Current The current knob SV is used to se...

Page 8: ...for the set period and then stay lit 4 Startup Lock Time The startup lock time is set using the startup lock time knob LOCK The startup lock time can be set to between 0 and 30 s Turn the knob while t...

Page 9: ...s 2 Make sure to use setting values appropriate for the controlled object Failure to do so can cause unintended operation and may result in accident or corruption of the product 3 Do not use thinner o...

Page 10: ...ply are connected internally so the K8AB AS will not operate normally if an unwanted current path exists If an unwanted current path exists use a K8AB model with an AC power supply or use an isolated...

Page 11: ...rating value 25 operating time 0 1 s startup lock timer 0 1 to 30 s set according to the duration of the startup current The K8AB AS3 can be set to between 10 to 100 of the rated current 10 A to 100 A...

Page 12: ...ice of the product on which liability is asserted IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS W...

Reviews: