99
Appendix B
List of Settings
Menu
Parameter
Setting range
Unit
Set value
sUset
sU.hh
HH set value
–19999 to 99999
---
Setting values menu
sU. h
H set value
–19999 to 99999
---
sU. l
L set value
–19999 to 99999
---
sU.ll
LL set value
–19999 to 99999
---
scale
inp.2
Input value 2
–19999 to 99999
---
Scaling menu
dsp.2
Display value 2
–19999 to 99999
---
inp.1
Input value 1
–19999 to 99999
---
dsp.1
Display value 1
–19999 to 99999
---
decĆp
Decimal point position
%%%%%
/
%.%%%%
/
%%.%%%
/
%%%.%%
/
%%%%.%
setup
Setup menu
inĆt
Input range
DC voltage input:
a Ud
to
e Ud
DC current input:
a ad
to
d ad
AC voltage input:
a Ua
to
d Ua
AC current input:
a aa
to
d aa
---
fre
Power supply frequency
50/60
Hz
uĆno
Communications unit no.
00 to 99
---
bps
Baud rate
1200/2400/4800/9600/19200/
38400
bps
len
Word length
7/8
bit
sbit
Stop bits
1/2
bit
prty
Parity bits
None/Even/Odd
---
opt
Option menu
aUg
Average processing
No average processing
Movement average processing:
2, 4, 8, 16, or 32 times
Simple average processing:
2, 4, 8, 16, or 32 times
---
stine
Startup compensation time
0.0 to 99.9
s
his
Hysteresis
1 to 9999
---
cĆout
Comparative output pattern
Standard output, zone output, or
level output
---
sleety
H linear output range
–19999 to 99999
---
sleety
L linear output range
–19999 to 99999
---
rĆl
Remote/local programming
Remote or local programming
---