51
Standby Sequence
When the K3NH is tuned on, the K3NH will have no output until the measured
value is within the PASS range. This function avoids unnecessary output until
the output is within the measurement range after the power is turned ON.
Setting
Unit
Default
ON/OFF
---
OFF
This setting is only available for the K3NH with the Comparative Output Units.
Follow the steps described below to set the standby sequence to ON.
Set Value LED Display Model
Basic Model
1, 2, 3...
1. Press the Mode Key for more than one second while the
opt
option menu is
displayed. The
aUg
average processing setting will appear.
Set Value LED Display Model
Basic Model
2. Repeatedly press the Mode Key until the
stdby
standby sequence setting is
displayed.
Set Value LED Display Model
Basic Model
3. Press the Shift Key to display present set value
off
for changing. The
PROG indicator will flash.
Set Value LED Display Model
Basic Model
4. Press the Up Key to set the value to
on
. The setting will be validated auto-
matically if no change is made for five seconds. The
stdby
standby se-
quence setting will be displayed again.
Note Press the Mode Key to enter the setting immediately. The next pa-
rameter will be displayed for setting.
Set Value LED Display Model
Basic Model
stdby
FUNCTION
SETTING
MODELS
SETTING
EXAMPLE
Setting Mode
Section 3-2