H8BM-R

10

Setting Counters That Will Not Use the Machine 

Stoppage Output (3-stage Type)

The machine stoppage output will not be 

used for counters for which the machine 

stoppage value has been set to +99999 

(+9999.9 h/+9999.9 s).

Setting Counters That Will Not Be Used

Input and output operations will not 

occur for counters for which the forecast 

value has been set to 0 (0.0 h/0.0 s).

If the forecast value is set to 0 (0.0 h/0.0 s), the 
pre-forecast and machine stoppage values will 
automatically be set to 0 (0.0 h/0.0 s).

Setting Counters to Be Used as Total Counters/Timers

Counters can be used as total counters/

timers if the forecast value for that 

counter is set to 999999 (99999.9 h/

99999.9 s).

The machine stoppage output will no longer be 

output for that counter.

When using a counter as a total counter, the 

forecast output for that counter when the count 

value changes from 999999 to 0 will be a one-

shot output of 20 ms to indicate a carry.

Press the 

 Key (or turn ON the 

counter No. selection input) in RUN 

mode to check the count value for each 

counter.

The counter number changes in sequence 

each time the 

 Key is pressed (or the input turns ON), from 1 through 

9, then back to 1.

Note: However, any counter whose forecast value is set to 0 (0.0 h/0.0 s) will be 

skipped.

Timer Operation Display

The period on the count value display 

will flash while the count input is ON and 

the Timer is in h mode.

The timer operation measures time by totaling 

the ON time of the count input.

1. Resetting Individual Counters

(1) Press the 

 Key (or turn ON the 

counter number selection input) to 
select the counter to be reset.

The counter value can be reset in all modes 

except initial setting mode and re-monitor 

mode.

(2) Press the 

 Key (or turn ON 

the reset input) to reset the count 
value to 0 for that counter only.

2. Resetting of All Counters at the Same Time

Press and hold both the 

 and 

 Keys for 3 seconds to reset the 

count value for all counters to 0.

The same operation is achieved by 
simultaneously turning ON the counter number 
selection and reset inputs for 3 seconds.

Press and hold the 

 and 

 

Keys for 3 seconds to reset the count 
values, pre-forecast values, forecast 
values, and machine stoppage values to 
0 for all counters. 

The counter number after All Clear has been 
executed will automatically change to 1.

The pre-forecast value, forecast, and machine stoppage status 
display will be as follows:

Pre-forecast Values (3-stage 
Type)

The output display for counters for 
which the count value has reached the 
pre-forecast set value will be lit.

Pre-forecast values are only displayed as a 
message and are not output.

Forecast Outputs

A red indicator will light at the top of the 
output display section for the lit counter 
number and the output will turn ON.

Machine Stoppage Output (3-
stage Type)

The entire background will alternate 
between red and green and the 
output display for the counter with a 
machine stoppage will flash.

Note: If the pre-forecast, forecast, or machine 

stoppage output turns ON, the counter 
number display will automatically change 
to that number and the count value will be 
displayed (in RUN mode only).

4. Special Set Values

5. Checking Count Values (RUN Mode)

6. Other Indicators

0

7

99999

00

7

99999

0

9

0

0

8

999999

9000

1

100000

C

N

N

o.

C

N

N

o.

1

2

3

4

5

6

7

8

9

00

1

10000

7. Deleting Count Value

8. All Clear

9. Control Output Display

100000

8

100000

C

N

N

o.

0

8

100000

RESET

0

a

100000

C

N

N

o.

RESET

23456

3

200000

0

1

0

RESET

SET

90000

1

100000

100000

1

100000

110000

1

100000

Summary of Contents for H8BM-R Series

Page 1: ...terminals Degree of protection IP54 oil proof type case front Input mode Up Output mode F mode Operation continues even when setting is reached Reset system External manual resets Timer operation Yes...

Page 2: ...ying metal parts Dielectric strength voltage 1 000 VAC 50 60 Hz for 1 min between current carrying terminals and exposed non current carrying metal parts Impulse withstand voltage 1 kV between power t...

Page 3: ...hts Forecast 9 outputs Each of these outputs turns ON when its forecast value has been reached When a total counter is used output one shot signals as carry signals Retain outputs until count values a...

Page 4: ...OM 8 9 10 11 12 13 14 RUN output Machine stoppage output Forecast output 1 Forecast output 2 Forecast output 3 Forecast output 4 Forecast output 5 1 2 3 4 5 6 7 Power supply 0 V Power supply 24 V Fore...

Page 5: ...ndicators light to show that the count value has reached the preset value and that the output has turned ON Time Range Indicator s seconds h hours I O Inhibit Indicator Indicates that the I O inhibit...

Page 6: ...cutout is as shown below according to DIN 43700 The mounting panel thickness must be 1 to 5 mm Mount the Counter so that the ambient temperature will not exceed 55 C Spacing with Other Devices Provide...

Page 7: ...s of the same size and type can be inserted into a single terminal 17 Separate the input devices input wiring and Counter as far as possible from sources of noise and power lines carrying noise 18 The...

Page 8: ...e 23456 3 200000 23456 3 200000 23456 3 500 23456 3 10000 Normal Mode Key Press for 4 s min Press for 4 s min This mode is for the operational state The present value set value counter number and outp...

Page 9: ...to pre forecast value mode is automatically displayed 2 Press the Key or turn ON the counter number selection input to select the counter whose data is to be set or changed Next press the Key to set...

Page 10: ...modes except initial setting mode and re monitor mode 2 Press the Key or turn ON the reset input to reset the count value to 0 for that counter only 2 Resetting of All Counters at the Same Time Press...

Page 11: ...ET Key protection is to be set Press the Key to enter the setting Note 1 The Reset of All Counters and All Clear using the RESET Key are disabled if the RESET Key Protection function is turned ON 2 Ke...

Page 12: ...eset input turns ON the re monitor value will flash 3 times and the only the count value for that counter will be returned to the value prior to being reset The following displays are made when errors...

Page 13: ...ther in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity...

Reviews: