H8BM-R
11
This mode is for setting a number of convenient functions.
10. Initial Setting Mode
23456
3
200000
count
30h
MODE
ti rng
1
01
MODE
short
9
MODE
eset
on
MODE
ode
off
MODE
set
off
MODE
ult
off
MULTI
MODE
N
ormal
Mode
Press for 4 s min.
MODE
Key
MODE
Key
MODE
Key
MODE
Key
MODE
Key
MODE
Key
MODE
Key
MODE
Key
Initial
Setting
Mode
1. Max. Counting Speed
Switching
2. Time Rages
3. Short Function
4. RESET Key Protection
Mode
5. MODE Key Protection
Mode
6. SET Key Protection
Mode
7. Multiplication Counter
•
Refer to page 8 for the normal modes.
•
If the mode is switched to the initial setting mode during operation,
operation will continue.
•
The characters displayed in reverse video are the default settings.
Counter 1 inputs can be input to other counters.
ex. if “5” is selected, Counter 1 inputs can be input to counters 2 to 5.
•
Press the
Key and select the number of counters for which the short
function is to be enabled.
•
Press the
Key to enter the setting.
Note: The short input is read only when the power is turned ON. They are ignored if
input during operation.
UP
→
OFF
→
2
→
3
→
4
→
5
→
6
→
7
→
8
9
SET
The RESET Key can be protected.
•
Press the
Key and select the counter for which RESET Key protection is
to be set.
•
Press the
Key to enter the setting.
Note 1. The Reset of All Counters and All Clear using the RESET Key are disabled
if the RESET Key Protection function is turned ON.
2. Key Protection function is activated by setting the Dip Switch to 10.
UP
O
N
(ch1 to 9)
→
O
N
(ch
8
/9)
→
O
N
(ch9)
→
OFF
SET
The max. counting speed switching for counters 8 and 9 can be
changed.
•
Press the
Key to switch between
and 500 Hz.
•
Press the
Key to enter the set value.
UP
30 Hz
SET
The Timer time rages can be changed.
•
Press the
Key to change the time rages.
Select the counter number.
•
Press the
Key to switch between
and 0.1 s.
•
Press the
Key to enter the set value.
Note: The time unit is displayed when the counter is set to a timer on the DIP switch.
C
N
T
N
o.
UP
0.1 h
SET
The MODE Key can be protected.
•
Press the
Key to switch between
and on.
•
Press the
Key to enter the setting.
Note: Key Protection function is activated by setting the Dip Switch to 10.
UP
off
SET
The SET Key can be protected.
•
Press the
Key to switch between
and on.
•
Press the
Key to enter the setting.
Note: Key Protection function is activated by setting the Dip Switch to 10.
UP
off
SET
•
Press the
Key to switch between
and on.
•
Press the
Key to enter the setting.
Note: A Multiplication Counter is a batch counter that increments the count of
counter 9 each time the forecast value of counter 1 is reached.
UP
off
SET