H8BM-R
9
●
Setting/Changing Forecast Value
1. In the RUN mode, press the
Key to enter the forecast
value setting mode.
•
The same counter number as in the RUN
mode is displayed after changing to
forecast value mode.
2. Press the
Key (or turn ON
the counter number selection
input) to select the counter whose
data is to be set or changed.
•
The counters are selected in sequence
each time the
Key is pressed, from
1 through 9, then back to 1.
•
A counter can also be selected by inputting the counter number selection
input.
3. Use the
Keys (
) to
change the values of the digits.
•
When an
Key is pressed, the
corresponding digit starts flashing.
•
The preset value is zero-suppressed. Each
time the
Key is pressed, the value
changes in sequence,
from 1
→
2
→
3
→
4
→
5
→
6
→
7
→
8
→
9
→
0.
In the following example, the forecast
value of counter 2 is set to 35000.
4. Press the
Key to enter the
set value.
•
If no key is pressed within 5 seconds after
the
Key has been pressed, RUN
mode is automatically restored.
(The display is changed automatically
after the set forecast value has
flashed.)
●
Setting and Changing Pre-forecast Values (3-stage
Type)
1. Press the
Key to enter the
pre-forecast value setting mode.
•
The same counter number as in the
forecast value setting mode is displayed
after changing to pre-forecast value mode.
•
“-” is automatically displayed.
2. Press the
Key (or turn ON
the counter number selection
input) to select the counter whose
data is to be set or changed.
Next, press the
Key
(
) to set or change the pre-
forecast value.
•
The
Key does not need to be pressed if the counter does not need to
be changed.
3. Press the
Key to enter the
set value.
•
If no key is pressed within 5 seconds after
the
Key has been pressed, the
RUN mode is automatically restored.
●
Setting and Changing the Machine Stoppage Value (3-
stage Type)
1. Press the
Key to enter the
Machine Stoppage Value setting
mode.
•
The same counter number as in the pre-
forecast value setting mode is displayed
after changing to machine stoppage value
setting mode.
•
“+” is automatically displayed.
2. Press the
Key (or turn ON
the counter number selection input)
to select the counter whose data is
to be set or changed.
Next, press the
Key
(
) to set or change the
machine stoppage value.
•
The
Key does not need to be pressed if the counter does not need to
be changed.
3. Press the
Key to enter the
set value.
•
If no key is pressed within 5 seconds after
the
Key has been pressed, the
RUN mode is automatically restored.
3. Setting/Changing Data
0
1
100000
MODE
0
2
0
C
N
T
N
o.
C
N
T
N
o.
1
→
2
→
3
→
4
→
5
→
6
→
7
→
8
→
9
0
2
10000
0
2
35000
UP
1
6
to
UP
UP
1
→
2
→
3
→
4
→
5
→
6
→
7
→
8
→
9
→
0
0
2
35000
SET
SET
0
2
35000
0
2
0
--
MODE
0
2
1000
--
C
N
T
N
o.
UP
1
5
to
C
N
T
N
o.
0
1
1000
--
SET
SET
0
2
0
MODE
0
2
2500
C
N
T
N
o.
UP
1
5
to
C
N
T
N
o.
0
2
2500
SET
SET