47
Setup the GRT1-PRT Configuration
Section 3-3
Editing SmartSlice I/O Unit
Settings
After making the I/O configuration selection, the settings of individual Smart-
Slice I/O Units can be set or changed. To do this, perform the following steps.
1,2,3...
1.
Select the SmartSlice I/O Unit in the I/O Configuration.
2.
Press the
Edit
button below the I/O Configuration list. The appropriate set-
ting window will pop up (see for example below).
Note
1.
In order to download/upload settings for individual SmartSlice I/O Units,
the DTM has to be on-line with the Physical GRT1-PRT Unit, i.e. it has to
be able to establish a connection with the device.
2.
In the case of the GRT1-AD2 some parameter settings will affect the I/O
Configuration, i.e. it will change the I/O size for that particular SmartSlice
I/O Unit. In that case, the I/O Configuration for the PROFIBUS Master Units
needs to be (re-)downloaded. If this is required, an appropriate warning
window will pop up.
3.
The configuration options and windows for individual SmartSlice I/O Units
are described in detail in
GRT1 Series SmartSlice I/O Units Operation
Manual
(W455)
Using the On-Line
Functions
At the bottom of the GRT1-PRT DTM are four buttons which will be Enabled
after the DTM has established communication with the physical device (via
the PROFIBUS Master Unit). Switching to on-line must be done via the FDT
Container. To switch to on-line, perform the following steps in Cx-Profibus.
1,2,3...
1.
In the Network view, select the GRT1-PRT and right-click the mouse.
2.
From the context menu, which pops up, select the option
Go Online
.
The buttons functions are discussed below.
Upload Button
Pressing the
Upload
button will initiate an upload of all SmartSlice I/O Infor-
mation, i.e. I/O Configuration, Unit types and Unit parameters. From this
upload, the I/O Configuration in the Configuration list will be assembled.
Note
Uploading may take some time, due to the amount of parameters.
Download Button
Pressing the
Download
button will initiate a download of all SmartSlice I/O
Information, i.e. I/O Configuration, Unit types and Unit parameters.
Compare Button
Pressing the
Compare
button will initiate a comparison between the I/O Con-
figuration and parameters of all SmartSlice I/O Units and the data stored
Summary of Contents for GRT1 - 27-11-2006
Page 3: ...ii ...
Page 9: ...viii ...
Page 13: ......
Page 49: ......
Page 95: ......
Page 105: ...86 Explicit Messages Appendix C ...
Page 109: ......
Page 111: ......