background image

12

Slim Relay

 

G3RV

Precautions

Precautions for Connection

Do not move the screwdriver up, down, or from side to side while it 
is inserted in the hole. Doing so may cause damage to internal 
components (e.g., deformation of the clamp spring or cracks in the 
housing) or cause deterioration of insulation.

Do not insert the screwdriver at an angle. Doing so may break the 
side of socket and result in a short-circuit.

Do not insert two or more wires in the hole. Wires may come in 
contact with the spring causing a temperature rise or be subject to 
sparks.

Insert the screwdriver along the hole wall as shown below.

If lubricating liquid, such as oil, is present on the tip of screwdriver, 
the screwdriver may fall out resulting in injury to the operator.

Insert the screwdriver into the bottom of the hole. It may not be 
possible to connect cables properly if the screwdriver is inserted 
incorrectly.

General Precautions

Do not use the product if it has been dropped on the ground. 
Dropping the product may adversely affect performance.

Confirm that the socket is securely attached to the mounting track 
before wiring. If the socket is mounted insecurely it may fall and 
injure the operator.

Ensure that the socket is not charged during wiring and 
maintenance. Not doing so may result in electric shock.

Do not pour water or cleansing agents on the product. Doing so 
may result in electric shock.

Do not use the socket in locations subject to solvents or alkaline 
chemicals.

Do not use the socket in locations subject to ultraviolet light (e.g., 
direct sunlight). Doing so may result in markings fading, rust, 
corrosion, or resin deterioration.

Do not dispose the product in fire.

Removing from Mounting Rail

To remove the socket from the mounting rail, insert the tip of 
screwdriver in the fixture rail, and move it in the direction shown 
below.

 

Screwdriver

Summary of Contents for G3RV

Page 1: ...G3RV SL Classification Enclosure rating Input voltage Type of connection Contact form SPST Plug in terminals General purpose Unsealed AC DC Screw terminals G3RV SL700 Push in terminals G3RV SL500 Inp...

Page 2: ...VDC 12 mA 21 6V 24 VAC DC 20 mA 21 mA 11 mA 21 6V 48 VAC DC 10 mA 11 mA 6 mA 43 2V 110 VAC 7 5 mA 8 2 mA 99V 230 VAC 7 3 mA 8 6 mA 207V Rated voltage Rated current Must operate voltage Must release vo...

Page 3: ...icing or condensation Operating 30 55 C with no icing or condensation Ambient humidity 45 85 RH Weight Approx 38 g Pollution degree 2 Degree of protection according to IEC 60529 IP20 Rated Impulse Wit...

Page 4: ...e Current Non repetitive Non repetitive Keep the inrush current to half the rated value if it occurs repetitively The values shown by the solid line are for non repetitive inrush currents Mounting Dis...

Page 5: ...tion Connection P2RVC 8 O F PLC Output Interface for 8x G2RV SL700 G3RV SL700 series PNP type Ribbon cable connector 10 Pole IEC603 1 Input Rated voltage 30 VAC VDC max Current capacity 0 5 A per chan...

Page 6: ...Green DC12V AC Yes 2A at 100 to 240VAC G3RV 202S DC12 G3RV SL700 500 A DC12 DC24V G3RV 202S DC24 G3RV SL700 500 A DC24 AC DC24V G3RV SL700 500 A AC DC24 AC DC48V G3RV SL700 500 A AC DC48 AC110V G3RV...

Page 7: ...minimum order Red R Blue S Black B P2RVM 030 3 60 pcs box minimum order P2RVM 040 4 60 pcs box minimum order P2RVM 100 10 20 pcs box minimum order P2RVM 200 20 20 pcs box minimum order Max current EN...

Page 8: ...n P2RV S 50 plates Provides isolation between adjacent relays to achieve 400 V isolation Five M2 5 6 6 2 max 99 2 7 1 88 9 26 1 47 2 70 9 83 106 7 max 92 7 max 35 Input circuit 24 V DC Terminal Arrang...

Page 9: ...ew Other Input Voltage Terminal Arrangement Internal Connections Top View 12 V DC Terminal Arrangement Internal Connections Top View 6 2 max 99 2 88 9 7 1 24 6 46 69 8 82 9 106 7 max 97 4 max 35 G3RV...

Page 10: ...tool Applicable Wires Applicable Wire Sizes G3RV SL700 Series Box clamp technology G3RV SL500 Series Push in technology Tightening torque G3RV SL700 Series 0 4Nm 2 5 dia 3 0 mm max Cannot be used Fla...

Page 11: ...conductor into the connection hole No other tools are required Note In case of wiring stranded wires without ferrules screwdriver should be inserted before inserting the wire Screwdriver should be re...

Page 12: ...e to connect cables properly if the screwdriver is inserted incorrectly General Precautions Do not use the product if it has been dropped on the ground Dropping the product may adversely affect perfor...

Page 13: ...Induction will be generated and cause malfunction or damages Be sure to conduct wiring with the power supply turned OFF Touching the terminals when they are charged may occationally result in minor el...

Page 14: ...ducts in the customer s application or use of the product Take all necessary steps to determine the suitability of the product for the systems machines and equipment with which it will be used Know an...