Page 2: ...ser manual and warnings carefully before installation Contents Description 3 Data sheet 4 Max DC load 4 Connection 5 LED Display Codes 5 DMX FAIL Function 7 Select operating mode 8 RDM 11 Factory Reset 13 Dimensions 14 CE Conformity 16 Disposal 16 Risk Notes 17 ...

Page 3: ...H works with supply voltages from 12V up to 24V DC DMX FAIL Function An adjustable DMX FAIL function offers the option to hold the current state HOLD or to adopt a predefined value if the DMX signal fails RDM support The DMX Relais 2 INRUSH allows the configuration via RDM or DMX Several operating modes The DMX Relais 2 INRUSH offers several operating modes which can be set via jumper or RDM Hyste...

Page 4: ...resis 100 150 Exclusive Monostable 1Second FogControl Output 2 potential free switching contacts NO 165A 20ms peak switch on current AC each max 8A 250V DC According to the max DC load graph Connection Screw terminals Dimensions 64 2mm x 82mm Max DC load The maximum current the switch contacts of the DMX RELAIS 2 INRUSH can switch is shown in the following graph depending on the switching voltage ...

Page 5: ...DMX RELAIS 2 INRUSH 5 Connection Switch contact AC each max 8A 250V DC According to the max DC load graph 165A 20ms peak switch on current ...

Page 6: ... lights is equal to the status number Event number Error Description 1 No DMX There is no DMX input signal 2 Addressingerror Please check the adjusted DMX Address 3 DMX Signal error An invalid DMX input signal is detected Addressing The starting address is adjustable via the DIP switches Thereby switch 1 has the valency 20 1 switch 2 valency 21 2 and so on until switch 9 has the valency 28 256 The...

Page 7: ...witch10 OFF DMX HOLD not active If HOLD is switched on switch 10 ON the last received DMX values are remained in case of a DMX signal failure If HOLD is switched off switch 10 OFF the DMX values are replaced with a value set by RDM in case of a DMX signal failure In the delivery state this value is 0 so that the relays switch off In case of a power failure the DMX values held with HOLD are discard...

Page 8: ... Output 1 ON 2 0 127 Output 2 OFF 128 255 Output 2 ON For this operation mode choose via RDM the Personality 1 or open all MODE jumper 1 5 Hysteresis 0 1 In this operating mode both relays switch independently of each other each via one DMX channel The switching threshold Hysteresis is 0 1 which means that the relay is switched off when the DMX value is 0 and that the relay is switched on when the...

Page 9: ...esn tchange 150 255 Output 1 ON 2 0 100 Output 2 OFF 101 149 Output 2 doesn tchange 150 255 Output 2 ON For this operation mode choose via RDM Personality 3 Exclusive Jalousie Control In this operation mode both relays are turned on with one DMX channel as soon as the DMX value is 128 or higher However not both relays can be switched on at the same time DMX Channel DMX Value Function 1 0 127 Outpu...

Page 10: ...gControl In this operation mode both relays are controlled via one DMX channel Therefore output 1 is for the heating element and output 2 for the pump An internal timer allows an automatically fog output For this operation mode choose via RDM the Personality 6 or close only MODE jumper 1 DMX Channel DMX Value Function 1 0 7 Device off aus 8 20 Device on no fog emission 21 40 Timer 10s on 300s off ...

Page 11: ...o OFF A DMX start address set by the address switches is always prior This device supports the following RDM commands Parameter ID Discovery Command SET Command GET Command ANSI PID DISC_UNIQUE_BRANCH E1 20 DISC_MUTE E1 20 DISC_UN_MUTE E1 20 DEVICE_INFO E1 20 SUPPORTED_PARAMETERS E1 20 PARAMETER_DESCRIPTION E1 20 SOFTWARE_VERSION_LABEL E1 20 DMX_START_ADDRESS E1 20 DEVICE_LABEL E1 20 MANUFACTURER_...

Page 12: ...e device serial number GET Send PDL 0 Receive PDL 21 21 Byte ASCII Text IDENTIFY_MODE PID 0xD402 Stellt den Mode ein der mit IDENTIFY_DEVICE ausgeführt wird GET Send PDL 0 Receive PDL 1 1 Byte IDENTIFY_MODE_ID SET Send PDL 1 1 Byte IDENTIFY_MODE_ID Receive PDL 0 IDENTIFY_MODE_ID Funktion 0 FULL Identify All relays switch ON OFF simultaneously and the status LED flashes 1 LOUD Identify The relays s...

Page 13: ...r supply Set DIP switch 1 up to 10 to ON Turn on the device turn on power supply The LED lights up 20x during ca 3 seconds While the LED lights up set DIP switch 10 to OFF Now the Factory Reset is executed The LED lights up with 4 short light pulses Turn off the device turn off power supply Now the device can be used If a Factory Reset is needed again this procedure can be repeated at any time ...

Page 14: ...DMX RELAIS 2 INRUSH 14 Dimensions All details in mm ...

Page 15: ...DMX RELAIS 2 INRUSH 15 Accessory Top hat railhousing700 Power supply 12V ...

Page 16: ...h the EMC directive 2014 30 EU is necessary Disposal Electronical and electronic products must not be disposed in domestic waste Dispose the product at the end of its service life in accordance with applicable legal regulations Information on this can be obtained from your local waste disposal company Warning This device is no toy Keep out of the reach of children Parents are liable for consequent...

Page 17: ...the board must be connected and adjusted to foreign components according to the device paperwork This work can only be done by qualified personnel which read the full device paperwork and understand it Operating risk The Change or the operation under special conditions of the installed systems components could as well as hidden defects cause to breakdown within the running time Misusage risk Any n...

Page 18: ...ad using electronic systems All information contained in this manual was arranged with largest care and after best knowledge Nevertheless errors are to be excluded not completely It is pointed out that neither a guarantee nor the legal responsibility or any liability for consequences which are due to incorrect information is assumed This document does not contain assured characteristics The guidan...