Table: Camera Setting (Camera Image Input) - Frame/Field
Item
Set Value
[Factory
defaults]
Description
[Frame]
Measurements are made in units of frames.
Frame/Field
Field
Measurements are made in units of fields. Select
"Field" when you prefer shorter image input time
rather than higher accuracy.
Processing becomes faster since each image is scanned
while skipping one scan line per two consecutive lines,
but the measurement accuracy lowers since the vertical
resolution of images lowers.
For the following operations, see
Setting up [Camera Image Input]
Number of Lines to be Read
By narrowing the image range to be scanned, the image scan time can be shortened.
Set the range taking the offset of the measured object into consideration.
The part of the image narrowed down by the start line and the end line will be displayed
in the "Image display" area of the ProcItem Setting window or of the Main screen.
Note
About minimum lines
The minimum lines (the minimum number of lines between the start and end
lines) are 12 lines.
About coordinate values
Summary of Contents for FZ2 Series
Page 1: ...Cat No Z275 E1 01 FZ2 Series Vision Sensors USER S MANUAL...
Page 6: ...Operation Flow Here describes the operation flow...
Page 19: ...Input Operation This section describes the basic operations of input devices of this product...
Page 23: ...The numerical value is input 3 Tap OK Verify the value and close the numeric keyboard...
Page 51: ...6 Tap OK when drawing is over The settings are registered...
Page 62: ......
Page 66: ......
Page 90: ...The Rename Unit window closes and the processing unit is renamed...
Page 97: ...3 Tap OK The scene switches...
Page 100: ...Locating Measurement Objects Not Inclined...
Page 101: ......
Page 102: ...Locating Measurement Objects Inclined Internal and External Measurement...
Page 103: ...Presence Measurement...
Page 104: ...Dimension Measurement Measurement...
Page 105: ...Burr Measurement Text Comparison Measurement Defects Measurement...
Page 106: ...Quantity Measurement Measurement Mixing Measurement...
Page 107: ...Measuring Height 3D Measuring Position of Holes 3D...
Page 108: ......
Page 123: ......
Page 140: ...Scene data is deleted 5 Tap Close...
Page 147: ...4 Tap Yes Scene group data is deleted 5 Tap Close...
Page 168: ......
Page 203: ......
Page 329: ...value 0 000 Field of view Calculated value 640 This is an actual dimension in the X direction...
Page 410: ...limit Lower limit 0 to 255 vividness This can only be set when Fine is selected...
Page 416: ...For the following operations see Setting up Color Data...
Page 423: ...Region Setting Color Data...
Page 426: ...133 Lower limit for density deviation for monochrome cameras only Set Get 0 to 127...
Page 461: ...For the following operations see Setting up Flexible Search...
Page 475: ...For the following operations see Setting up Edge Position...
Page 494: ...For the following operations see Setting up Edge pitch...
Page 509: ...Please verify the sequent operations by following Setting up Defect...
Page 524: ...For the subsequent operations see Setting up Fine matching...
Page 568: ...For the subsequent operations see Setting up Gravity and Area...
Page 572: ...For the following operations see Setting up Gravity and Area...
Page 588: ......
Page 592: ...For the following operations please refer to Setting up Labeling...
Page 640: ...For the subsequent operations see Setting up Character Inspection...
Page 648: ...Reduce the measurement region size in Region Setting Region Setting Character Inspection...
Page 688: ...edge For the subsequent operations see Setting Up Scan Edge Position...
Page 960: ...color R 157 Background color G Set Get 0 to 255 158 Background color B Set Get 0 to 255...