background image

6

* Items indicated with an asterisk are dedicated items, and cannot be substituted.

Peripheral Device

Input Device

Camera

LCD monitor

Power Supply

FZ-M08 (8.4-inch)

FZ-VM (2 m, 5 m)

Camera cable
FZ-VS (2 m, 5 m, 10 m)

3D vision camera FZD-STC2M

USB memory
FZ-MEM1G

Mouse, track ball
(Commercially available USB devices)

Box type FZD-550-10

FZD-555-10

LCD integrated type FZD-500-10/FZD-505-10

Front view

Touch pen (standard accessory)

Right-side view

Controller

*

Controller

Monitor cable

*

*

Camera cable

*

*

*

*

Elastic camera cable
FZ-VSB (2 m, 5 m, 10 m)

Right angle camera cable
FZ-VSL (2 m, 5 m, 10 m)

Recommended Model
   By OMRON Corporation
   S8VS-18024

Use the monitor to check images and display the condition-setting 
menus. The Controller performs the image processing specified by 
the user settings and outputs the measurement results.

The Controlle r perform s the image 
processing specified by the user settings 
and outputs the measurement results.

Use the monitor to check images 
and display the condition-settin g 
menus.

Detects workpieces as images.

Basic Configuration 

Controller FZD

Standalone camera FZ-SC/FZ-S

FZ-SC2M/FZ-S2M

fz3_4ch_setup_E.book  Page 6  Friday, August 7, 2009  5:45 PM

Summary of Contents for FZ Series

Page 1: ...ical engineering To ensure correct use please read this manual thoroughly to deepen your understanding of the product Please keep this manual in a safe place so that it can be referred to whenever nec...

Page 2: ...ON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES Please refer to separate catalogs for OMRON s safety rated products OMRON shall not be responsible for conformity with any standards cod...

Page 3: ...ever disassemble apply pressure that would deform heat to 100 C or higher or incinerate the Controller Since this product emits a visible light that may have an adverse affect on the eyes do not stare...

Page 4: ...50 C 122 F Provide a forced air fan cooling or air conditioning if the ambient temperature is near 50 C 122 F so that the ambient temperature never exceeds 50 C 122 F Do not install in this orientatio...

Page 5: ...ediately after power is turned ON When using the RESET input to synchronize startup timing wait at least 15 second after the Controller s power supply is turned ON before turning ON the RESET signal M...

Page 6: ...3 H900 10 FZ3 H905 10 Front view Touch pen standard accessory Right side view Controller Controller Monitor cable Recommended Model By OMRON Corporation S8VS 18024 Intelligent camera Automatic focus c...

Page 7: ...cable Elastic camera cable FZ VSB 2 m 5 m 10 m Right angle camera cable FZ VSL 2 m 5 m 10 m Recommended Model By OMRON Corporation S8VS 18024 Use the monitor to check images and display the condition...

Page 8: ...232C RS 422 connector RS 232C RS 422 connector I O connector control lines data lines I O connector control lines data lines The following items can be connected to USB ports Commercially available tr...

Page 9: ...A max 1 1V max 5 ms max 0 7 ms max Input signals STEP0 ENCTRIG_Z0 STEP1 ENCTRIG_Z1 ENCTRIG_A0 to 1 ENCTRIG_B0 to 1 1 ON current ON voltage This refers to the current or voltage values needed to shift...

Page 10: ...ltage Load current ON residual voltage OFF leakage current Internal circuit 12 to 24 V DC 10 45 mA max 2 V max 0 2 mA max Input voltage ON current 1 ON voltage 1 OFF current 2 OFF voltage 2 ON delay O...

Page 11: ...2 Controller Use a shielded cable The maximum cable length is 15 m Use a compatible connector Recommended items RS CS control cannot be used Align the connector with the socket and press it straight i...

Page 12: ...e Bottom face 1 0 Mounting 1 2 3 Mounting the controller to the optional desktop stand The controller can be placed on a desk by attaching the optional desktop stand FZ DS to the rear of the controlle...

Page 13: ...5 10 FZ3 700 10 FZ3 705 10 FZ3 H700 10 FZ3 H705 10 FZ3 900 10 FZ3 905 10 FZ3 H900 10 FZ3 H905 10 FZD 500 10 FZD 505 10 Box type FZ3 350 10 FZ3 355 10 FZ3 H350 10 FZ3 H355 10 FZ3 750 10 FZ3 755 10 FZ3...

Page 14: ...ed When FZ S_ FZ SC_M FZ S_M is connected Approx 4 9 A max When FZ SF_ FZ SP_ is connected Approx 4 9 A max When FZ SLC___ FZ SZC___ is connected Approx 7 5 A max When FZD STC2M is connected Approx 4...