background image

8

I/O Connector

A1

A2

A3

A4

A5

A6

A7

A8

A9

A10

A11

A12

A13

A14

A15

A16

A17

A18

A19

A20

A21

A22

A23

A24

A25

B1

B2

B3

B4

B5

B6

B7

B8

B9

B10

B11

B12

B13

B14

B15

B16

B17

B18

B19

B20

B21

B22

B23

B24

B25

No.

Wire color Mark (red)

Function

Signal name

No.

COMIN

ENCTRIG_A1 (*2)

ENCTRIG_B1 (*2)

STEP1 (*2)/ 

ENCTRIG_Z1 (*2)

DSA1 (*2)

DI1

DI3

DI5

DI7

STGOUT1

STGOUT3

ERROR

COMOUT1

GATE1 (*2)

OR1 (*2)

READY1 (*2)

COMOUT2

DO1

DO3

DO5

DO7

DO9

DO11

DO13

COMOUT3

Orange

Gray

White

Yellow

Pink

Orange

Gray

White

Yellow

Pink

Orange

Gray

White

Yellow

Pink

Orange

Gray

White

Yellow

Pink

Orange

Gray

White

Yellow

Pink

Wire color Mark (blk)

Function

Signal name

Orange

Gray

White

Yellow

Pink

Orange

Gray

White

Yellow

Pink

Orange

Gray

White

Yellow

Pink

Orange

Gray

White

Yellow

Pink

Orange

Gray

White

Yellow

Pink

RESET

DSA0

DI0

DI2

DI4

DI6

STGOUT0

STGOUT2

RUN/BUSY1 (*2)

BUSY0

GATE0

OR0

READY0

DO0

DO2

DO4

DO6

DO8

DO10

DO12

DO14

DO15

Controller restart

Data send request signal

Command inputs

Strobe trigger output (*1)

Strobe trigger output (*1)

ON while in Run mode/ON during processing

ON during processing

ON for the set output time

Overall judgment result

ON when image input is allowed

Data output

Common for input signals

Encoder trigger input (Phase A)

Encoder trigger input (Phase B) 

Measurement trigger input/ 
Encoder trigger input (Phase Z) 

Data send request signal 

Command inputs

Strobe trigger output (*1)

Strobe trigger output (*1)

ON when there is an error.

Common for control signals

ON for the set output time

Overall judgment result

ON when image input is allowed

Common for output signals

Data output

Common for output signals

Load

Output terminal

COM IN

COM OUT

Input voltage

ON current *1

ON voltage *1

OFF current *2

OFF voltage *2

ON delay

OFF delay

Internal circuit

12 to 24 V DC  ±10 %

5 mA min.

8.8 V min.

0.5 mA max.

1.1V max.

5 ms max.

0.7 ms max.

[Input] signals: STEP0/ENCTRIG_Z0, STEP1/ENCTRIG_Z1,  
 

ENCTRIG_A0 to 1, ENCTRIG_B0 to 1

*1 ON current/ON voltage
 

This refers to the current or voltage values needed to shift from the OFF 

 ON state. The ON voltage value is the potential 

difference between each of the input terminals and COM IN.

*2 OFF current/OFF voltage
 

This refers to the current or voltage values needed to shift from the ON 

 OFF state. The OFF voltage value is the potential 

difference between each of the input terminals and COM IN.

COM IN

Input terminal

[Output] signals:

Output voltage

Load current

ON residual voltage

OFF leakage current

Internal circuit

12 to 24 V DC  ±10 %

45 mA max.

2 V max.

0.2 mA max.

Input voltage

ON current *1

ON voltage *1

OFF current *2

OFF voltage *2

ON delay

OFF delay

Internal circuit

12 to 24 V DC  ±10 %

5 mA min.

8.8 V min.

0.5 mA max.

0.8 V max.

0.1 ms max.

0.1 ms max.

COM IN

Input terminal

Output voltage

Load current

ON residual voltage

OFF leakage current

Internal circuit

12 to 24 V DC  ±10 %

45 mA max.

2 V max.

0.2 mA max.

Load

COM OUT

Output terminal

•Handling the output common terminals
COMOUT1: STGOUT0 to 1, RUN/BUSY1, ERROR, BUSY0, AOR0 to 1, GATE0 to 1   COMOUT2: READY0 to 1, DO0 to 7   COMOUT3: DO8 to 15
*1 This is a signal that is used when the strobe device is connected to the Controller.
*2 This signal is only available in the Random trigger mode.

Internal Specifications

[Input] signals: RESET, DI0 to DI7, DSA0, DSA1

NPN I/O type FZ3-300-10/FZ3-350-10/FZ3-H300-10/FZ3-H350-10/FZ3-700-10/FZ3-750-10/FZ3-H700-10

FZ3-H750-10/FZ3-900-10/FZ3-950-10/FZ3-H900-10/FZ3-H950-10/FZD-500-10/FZD-550-10

Parallel Interface

BUSY0, RUN/BUSY1, OR0 to 1, GATE0 to 1,  
ERROR, DO0 to 15, READY0 to 1

[Output] signals: When STGOUT0-3 are not used, 

connect the COM IN terminal.

ENCTRG_A0

ENCTRG_B0

STEP0/ 

ENCTRG_Z0

Encoder trigger input(Phase A)

Encoder trigger input(Phase B)
Measurement trigger input/Encoder 
trigger input(Phase Z)

fz3_4ch_setup_E.book  Page 8  Friday, August 7, 2009  5:45 PM

Summary of Contents for FZ Series

Page 1: ...ical engineering To ensure correct use please read this manual thoroughly to deepen your understanding of the product Please keep this manual in a safe place so that it can be referred to whenever nec...

Page 2: ...ON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES Please refer to separate catalogs for OMRON s safety rated products OMRON shall not be responsible for conformity with any standards cod...

Page 3: ...ever disassemble apply pressure that would deform heat to 100 C or higher or incinerate the Controller Since this product emits a visible light that may have an adverse affect on the eyes do not stare...

Page 4: ...50 C 122 F Provide a forced air fan cooling or air conditioning if the ambient temperature is near 50 C 122 F so that the ambient temperature never exceeds 50 C 122 F Do not install in this orientatio...

Page 5: ...ediately after power is turned ON When using the RESET input to synchronize startup timing wait at least 15 second after the Controller s power supply is turned ON before turning ON the RESET signal M...

Page 6: ...3 H900 10 FZ3 H905 10 Front view Touch pen standard accessory Right side view Controller Controller Monitor cable Recommended Model By OMRON Corporation S8VS 18024 Intelligent camera Automatic focus c...

Page 7: ...cable Elastic camera cable FZ VSB 2 m 5 m 10 m Right angle camera cable FZ VSL 2 m 5 m 10 m Recommended Model By OMRON Corporation S8VS 18024 Use the monitor to check images and display the condition...

Page 8: ...232C RS 422 connector RS 232C RS 422 connector I O connector control lines data lines I O connector control lines data lines The following items can be connected to USB ports Commercially available tr...

Page 9: ...A max 1 1V max 5 ms max 0 7 ms max Input signals STEP0 ENCTRIG_Z0 STEP1 ENCTRIG_Z1 ENCTRIG_A0 to 1 ENCTRIG_B0 to 1 1 ON current ON voltage This refers to the current or voltage values needed to shift...

Page 10: ...ltage Load current ON residual voltage OFF leakage current Internal circuit 12 to 24 V DC 10 45 mA max 2 V max 0 2 mA max Input voltage ON current 1 ON voltage 1 OFF current 2 OFF voltage 2 ON delay O...

Page 11: ...2 Controller Use a shielded cable The maximum cable length is 15 m Use a compatible connector Recommended items RS CS control cannot be used Align the connector with the socket and press it straight i...

Page 12: ...e Bottom face 1 0 Mounting 1 2 3 Mounting the controller to the optional desktop stand The controller can be placed on a desk by attaching the optional desktop stand FZ DS to the rear of the controlle...

Page 13: ...5 10 FZ3 700 10 FZ3 705 10 FZ3 H700 10 FZ3 H705 10 FZ3 900 10 FZ3 905 10 FZ3 H900 10 FZ3 H905 10 FZD 500 10 FZD 505 10 Box type FZ3 350 10 FZ3 355 10 FZ3 H350 10 FZ3 H355 10 FZ3 750 10 FZ3 755 10 FZ3...

Page 14: ...ed When FZ S_ FZ SC_M FZ S_M is connected Approx 4 9 A max When FZ SF_ FZ SP_ is connected Approx 4 9 A max When FZ SLC___ FZ SZC___ is connected Approx 7 5 A max When FZD STC2M is connected Approx 4...

Reviews: