background image

Authorized Distributor:

OMRON Industrial Automation Global: 

www.ia.omron.com

OMRON Corporation

Industrial Automation Company

Regional Headquarters

OMRON EUROPE B.V.
Sensor Business Unit

Carl-Benz-Str. 4, D-71154 Nufringen,
Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199

OMRON ELECTRONICS LLC

One Commerce Drive Schaumburg, 
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787

OMRON ASIA PACIFIC PTE. LTD.

No. 438A Alexandra Road # 05-05/08 (Lobby 2), 
Alexandra Technopark, Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711

OMRON (CHINA) CO., LTD.

Room 2211, Bank of China Tower, 
200 Yin Cheng Zhong Road, 
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200

Sensing Devices Division H.Q.
Application Sensors Division

Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81) 75-344-7068/Fax: (81) 75-344-7107

In the interest of product improvement,  
specifications are subject to change 
without notice.

Controller Specifications

LCD integrated type: Touch pen, mouse etc.

BOX type: Mouse or similar device

RS-232C/422: 1 channel

Ethernet 100BASE-TX/10BASE-T

17 inputs (RESET, STEP0/ENCTRIG_Z0, STEP1/ENCTRIG_Z1, DSA0 to 1, ENCTRIG_A0 to 1,

ENCTRIG_B0 to 1, DI0 to 7)

29 outputs (RUN/BUSY1, BUSY0, GATE0 to 1, OR0 to 1, READY0 to 1, ERROR, STGOUT0 to 3, DO0 to 15)

LCD integrated type: Integrated Controller and 12.1 inch TFT color LCD 

(Resolusion: XGA 1024

×

768)

BOX type: Analog RGB video output 1 channel (Resolusion: XGA 1024

×

768)

4 channels (supports USB1.1 and 2.0)

24 V DC (20.4 to 26.4 V DC)

Consumption of current varies depending on the type of camera connected.

When FZ-S_/FZ-SC_M/FZ-S_M is connected: Approx. 4.9 A max.

When FZ-SF_/FZ-SP_ is connected: Approx. 4.9 A max.

When FZ-SLC___/FZ-SZC___ is connected: Approx. 7.5 A max.

When FZD-STC2M is connected: Approx. 4.9 A max.

Between the group of external DC terminals and the ground terminal: 20M 

 

min.

(DC100V megger, with internal surge absober removed)

Between the group of external DC terminals and the ground terminal: 1,000 VAC, 50/60 Hz

10 mA max.

2 kV, pulse rise: 5 ns Pulse width: 50 ns

Burst continuing time: 15 ms Cycle: 300 ms

10 to 150 Hz, one-side amplitude 0.1 mm (Max. acceleration 15m/s

2

)

10 times for 8 minutes for each three direction

150 m/s

2

; 3 times each in 6 directions

Operating: 0 to +50 °C (with no icing nor no condensation) 

Ambient temperature specifiable. The cooling fan speed can be switched 

according to the setting. 

0 to +45 °C: Low speed, 0 to +50 °C: High speed

Storage: –20 to +65 °C (with no icing nor no condensation)

Operating and storage: 35 % to 85 % (no condensation)

No corrosive gases

D-type ground (ground resistance 100 

 

or less) * conventional class 3 ground

IEC60529  IP20

Indoor use

Maximum altitude of 2,000 m

Supply voltage fluctuations of +10 %, –15 % of the rated voltage

Installation category I

Pollution degree 2

ABS

LCD integrated type: Approx. 3.4 kg  Box type: Approx. 1.9 kg

Operation

Serial communications

Network communications

Parallel I/O

Monitor interface

USB interface

Power supply voltage

Current consumption

Insulation resistance

Dielectric strength

Leakage current

Noise resistance

Vibration resistance

Shock resistance

Ambient temperature 

range

Ambient humidity range

Ambient environment

Ground

Degree of protection

Environmental conditions

(according to  

IEC61010-1)

Case materials

Weight

fz3_4ch_setup_E.book  Page 1  Friday, August 7, 2009  5:45 PM

Summary of Contents for FZ Series

Page 1: ...ical engineering To ensure correct use please read this manual thoroughly to deepen your understanding of the product Please keep this manual in a safe place so that it can be referred to whenever nec...

Page 2: ...ON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES Please refer to separate catalogs for OMRON s safety rated products OMRON shall not be responsible for conformity with any standards cod...

Page 3: ...ever disassemble apply pressure that would deform heat to 100 C or higher or incinerate the Controller Since this product emits a visible light that may have an adverse affect on the eyes do not stare...

Page 4: ...50 C 122 F Provide a forced air fan cooling or air conditioning if the ambient temperature is near 50 C 122 F so that the ambient temperature never exceeds 50 C 122 F Do not install in this orientatio...

Page 5: ...ediately after power is turned ON When using the RESET input to synchronize startup timing wait at least 15 second after the Controller s power supply is turned ON before turning ON the RESET signal M...

Page 6: ...3 H900 10 FZ3 H905 10 Front view Touch pen standard accessory Right side view Controller Controller Monitor cable Recommended Model By OMRON Corporation S8VS 18024 Intelligent camera Automatic focus c...

Page 7: ...cable Elastic camera cable FZ VSB 2 m 5 m 10 m Right angle camera cable FZ VSL 2 m 5 m 10 m Recommended Model By OMRON Corporation S8VS 18024 Use the monitor to check images and display the condition...

Page 8: ...232C RS 422 connector RS 232C RS 422 connector I O connector control lines data lines I O connector control lines data lines The following items can be connected to USB ports Commercially available tr...

Page 9: ...A max 1 1V max 5 ms max 0 7 ms max Input signals STEP0 ENCTRIG_Z0 STEP1 ENCTRIG_Z1 ENCTRIG_A0 to 1 ENCTRIG_B0 to 1 1 ON current ON voltage This refers to the current or voltage values needed to shift...

Page 10: ...ltage Load current ON residual voltage OFF leakage current Internal circuit 12 to 24 V DC 10 45 mA max 2 V max 0 2 mA max Input voltage ON current 1 ON voltage 1 OFF current 2 OFF voltage 2 ON delay O...

Page 11: ...2 Controller Use a shielded cable The maximum cable length is 15 m Use a compatible connector Recommended items RS CS control cannot be used Align the connector with the socket and press it straight i...

Page 12: ...e Bottom face 1 0 Mounting 1 2 3 Mounting the controller to the optional desktop stand The controller can be placed on a desk by attaching the optional desktop stand FZ DS to the rear of the controlle...

Page 13: ...5 10 FZ3 700 10 FZ3 705 10 FZ3 H700 10 FZ3 H705 10 FZ3 900 10 FZ3 905 10 FZ3 H900 10 FZ3 H905 10 FZD 500 10 FZD 505 10 Box type FZ3 350 10 FZ3 355 10 FZ3 H350 10 FZ3 H355 10 FZ3 750 10 FZ3 755 10 FZ3...

Page 14: ...ed When FZ S_ FZ SC_M FZ S_M is connected Approx 4 9 A max When FZ SF_ FZ SP_ is connected Approx 4 9 A max When FZ SLC___ FZ SZC___ is connected Approx 7 5 A max When FZD STC2M is connected Approx 4...

Reviews: