background image

2

The following signal words are used in this manual. 

Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or 
may result in serious injury or death. Additionally there may be significant property damage. 

Meanings of Signal Words 

The following alert symbols are used in this manual. 

Meanings of Alert Symbols 

The following alert statements apply to the products in this manual. Each alert statement also appears at the locations needed in 
this manual to attract your attention.

Alert statements in this Manual 

Precautions for Safe Use 

WARNING

Indicate s general prohibition s for which there is no 
specific symbol. 

Indicate s the possibilit y of explosio n under specifi c 
conditions. 

This product is not designed or rated for ensuring safety of persons.
Do not use it for such purposes.

A lithium battery is built into the Controller and may occasionally combust, explode, or burn if not treated properly. Dispose of the Controller 
as industrial waste, and never disassemble, apply pressure that would deform, heat to 100°C or higher, or incinerate the Controller.

Since this product emits a visible light that may have an adverse affect on the eyes, do not stare directly into the light emitted 
from the LED. If a specular object is used, take care not to allow reflected light enter your eyes.

This product must be used according to the instruction manual. Failure to observe this may result in impairment of functions 
and performance of the product. 

WARNING

CAUTION

Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury 
or in property damage. 

Indicates the possibility of injury by high temperature under specific conditions. 

Do not open the cover. Doing so may result in electric shock from internally used high voltages.

Indicates the possibility of electric shock under specific 
conditions. 

Danger of burns
Do not touch the case while the LED is ON or just after power is turned OFF, since it remains extremely hot.

8.5 mm max.

8.5 mm max.

Indicates the possibility of laser radiation. 

CAUTION

The Controller complies with the following standards.

EN61326-1

fz3_4ch_setup_E.book  Page 2  Friday, August 7, 2009  5:45 PM

Summary of Contents for FZ Series

Page 1: ...ical engineering To ensure correct use please read this manual thoroughly to deepen your understanding of the product Please keep this manual in a safe place so that it can be referred to whenever nec...

Page 2: ...ON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES Please refer to separate catalogs for OMRON s safety rated products OMRON shall not be responsible for conformity with any standards cod...

Page 3: ...ever disassemble apply pressure that would deform heat to 100 C or higher or incinerate the Controller Since this product emits a visible light that may have an adverse affect on the eyes do not stare...

Page 4: ...50 C 122 F Provide a forced air fan cooling or air conditioning if the ambient temperature is near 50 C 122 F so that the ambient temperature never exceeds 50 C 122 F Do not install in this orientatio...

Page 5: ...ediately after power is turned ON When using the RESET input to synchronize startup timing wait at least 15 second after the Controller s power supply is turned ON before turning ON the RESET signal M...

Page 6: ...3 H900 10 FZ3 H905 10 Front view Touch pen standard accessory Right side view Controller Controller Monitor cable Recommended Model By OMRON Corporation S8VS 18024 Intelligent camera Automatic focus c...

Page 7: ...cable Elastic camera cable FZ VSB 2 m 5 m 10 m Right angle camera cable FZ VSL 2 m 5 m 10 m Recommended Model By OMRON Corporation S8VS 18024 Use the monitor to check images and display the condition...

Page 8: ...232C RS 422 connector RS 232C RS 422 connector I O connector control lines data lines I O connector control lines data lines The following items can be connected to USB ports Commercially available tr...

Page 9: ...A max 1 1V max 5 ms max 0 7 ms max Input signals STEP0 ENCTRIG_Z0 STEP1 ENCTRIG_Z1 ENCTRIG_A0 to 1 ENCTRIG_B0 to 1 1 ON current ON voltage This refers to the current or voltage values needed to shift...

Page 10: ...ltage Load current ON residual voltage OFF leakage current Internal circuit 12 to 24 V DC 10 45 mA max 2 V max 0 2 mA max Input voltage ON current 1 ON voltage 1 OFF current 2 OFF voltage 2 ON delay O...

Page 11: ...2 Controller Use a shielded cable The maximum cable length is 15 m Use a compatible connector Recommended items RS CS control cannot be used Align the connector with the socket and press it straight i...

Page 12: ...e Bottom face 1 0 Mounting 1 2 3 Mounting the controller to the optional desktop stand The controller can be placed on a desk by attaching the optional desktop stand FZ DS to the rear of the controlle...

Page 13: ...5 10 FZ3 700 10 FZ3 705 10 FZ3 H700 10 FZ3 H705 10 FZ3 900 10 FZ3 905 10 FZ3 H900 10 FZ3 H905 10 FZD 500 10 FZD 505 10 Box type FZ3 350 10 FZ3 355 10 FZ3 H350 10 FZ3 H355 10 FZ3 750 10 FZ3 755 10 FZ3...

Page 14: ...ed When FZ S_ FZ SC_M FZ S_M is connected Approx 4 9 A max When FZ SF_ FZ SP_ is connected Approx 4 9 A max When FZ SLC___ FZ SZC___ is connected Approx 7 5 A max When FZD STC2M is connected Approx 4...

Reviews: