9

I/O Connector

No.

Wire color Mark (red)

Function

Signal name

No.

Wire color Mark (blk)

Function

Signal name

Output terminal

COM IN

Input voltage

ON current *1

ON voltage *1

OFF current *2

OFF voltage *2

ON delay

OFF delay

Internal circuit

12 to 24 V DC  ±10 %

5 mA min.

8.8 V min.

0.5 mA max.

1.1V max.

5 ms max.

0.7 ms max.

[Input] signals: STEP0/ENCTRIG_Z0, STEP1/ENCTRIG_Z1, 
 

ENCTRIG_A0 to 1, ENCTRIG_B0 to 1

*1 ON current/ON voltage
 

This refers to the current or voltage values needed to shift from the OFF 

 ON state. The ON voltage value is the potential 

difference between each of the input terminals and COM IN.

*2 OFF current/OFF voltage
 

This refers to the current or voltage values needed to shift from the ON 

 OFF state. The OFF voltage value is the potential 

difference between each of the input terminals and COM IN.

[Output] signals:

Output voltage

Load current

ON residual voltage

OFF leakage current

Internal circuit

12 to 24 V DC  ±10 %

45 mA max.

2 V max.

0.2 mA max.

Input voltage

ON current *1

ON voltage *1

OFF current *2

OFF voltage *2

ON delay

OFF delay

Internal circuit

12 to 24 V DC  ±10 %

5 mA min.

8.8 V min.

0.5 mA max.

0.8 V max.

0.1 ms max.

0.1 ms max.

Output voltage

Load current

ON residual voltage

OFF leakage current

Internal circuit

12 to 24 V DC  ±10 %

45 mA max.

2 V max.

0.2 mA max.

Internal Specifications

[Input] signals: RESET, DI0 to DI7, DSA0, DSA1

PNP I/O type FZ3-305-10/FZ3-355-10/FZ3-H305-10/FZ3-H355-10/FZ3-705-10/FZ3-755-10/FZ3-H705-10 

FZ3-H755-10/FZ3-905-10/FZ3-955-10/FZ3-H905-10/FZ3-H955-10/FZD-505-10/FZD-555-10

Parallel Interface

BUSY0, RUN/BUSY1, OR0 to 1, GATE0 to 1, 
ERROR, DO0 to 15, READY0 to 1

[Output] signals: When STGOUT0-3 are not used, 

connect the COM IN terminal.

COM IN

Input terminal

COM OUT

Output terminal

Load

COM IN

Input terminal

COM OUT

Load

I/O Connector wiring is the same as NPN I/O type.

fz3_4ch_setup_E.book  Page 9  Friday, August 7, 2009  5:45 PM

Summary of Contents for FZ Series

Page 1: ...ical engineering To ensure correct use please read this manual thoroughly to deepen your understanding of the product Please keep this manual in a safe place so that it can be referred to whenever nec...

Page 2: ...ON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES Please refer to separate catalogs for OMRON s safety rated products OMRON shall not be responsible for conformity with any standards cod...

Page 3: ...ever disassemble apply pressure that would deform heat to 100 C or higher or incinerate the Controller Since this product emits a visible light that may have an adverse affect on the eyes do not stare...

Page 4: ...50 C 122 F Provide a forced air fan cooling or air conditioning if the ambient temperature is near 50 C 122 F so that the ambient temperature never exceeds 50 C 122 F Do not install in this orientatio...

Page 5: ...ediately after power is turned ON When using the RESET input to synchronize startup timing wait at least 15 second after the Controller s power supply is turned ON before turning ON the RESET signal M...

Page 6: ...3 H900 10 FZ3 H905 10 Front view Touch pen standard accessory Right side view Controller Controller Monitor cable Recommended Model By OMRON Corporation S8VS 18024 Intelligent camera Automatic focus c...

Page 7: ...cable Elastic camera cable FZ VSB 2 m 5 m 10 m Right angle camera cable FZ VSL 2 m 5 m 10 m Recommended Model By OMRON Corporation S8VS 18024 Use the monitor to check images and display the condition...

Page 8: ...232C RS 422 connector RS 232C RS 422 connector I O connector control lines data lines I O connector control lines data lines The following items can be connected to USB ports Commercially available tr...

Page 9: ...A max 1 1V max 5 ms max 0 7 ms max Input signals STEP0 ENCTRIG_Z0 STEP1 ENCTRIG_Z1 ENCTRIG_A0 to 1 ENCTRIG_B0 to 1 1 ON current ON voltage This refers to the current or voltage values needed to shift...

Page 10: ...ltage Load current ON residual voltage OFF leakage current Internal circuit 12 to 24 V DC 10 45 mA max 2 V max 0 2 mA max Input voltage ON current 1 ON voltage 1 OFF current 2 OFF voltage 2 ON delay O...

Page 11: ...2 Controller Use a shielded cable The maximum cable length is 15 m Use a compatible connector Recommended items RS CS control cannot be used Align the connector with the socket and press it straight i...

Page 12: ...e Bottom face 1 0 Mounting 1 2 3 Mounting the controller to the optional desktop stand The controller can be placed on a desk by attaching the optional desktop stand FZ DS to the rear of the controlle...