92
Chapter
4
Wiring Examp
le
s
F3SJ-A
User’s Manual
Input/Output Circuit and Applications
Connecting to an F3SX-E-L2R
•Emergency stop switch can be connected
•Door switch, two hand control, single beam, or relay unit can be used in combination with F3SX
•Various settings can be changed and input/output terminals can be monitored using the setting
support software for F3SX
2
7
5
4
3
1
8
6
15
10
12
13
14
16
9
11
S1
S2
11
12
22
21
DC24V
E1
A1
T11
T12
T21
T22
Y1
Y2
Y3
DC24V
E1
A2
DC24V
DC24V
COM
0V
SSC
AS3
AS2
AS1
SS1
SS2
FB
E1
DC24V
RY1
RY2
DC24V
E1
KM1
KM2
M
RY1
RY2
15
10
12
13
14
16
9
11
2
7
5
4
3
1
8
6
12
34
24
33
11
23
AC
K1
K2
KM1
KM2
Wiring when safety light curtain
F3SJ is not used
L2 Module
Emitter
Receiver
F3SJ (1st unit)
Model F39-JC A-L
cable for emitter
Model F39-JC A-D
cable for receiver
Communication
line (+) (Grey)
Communication
line (-) (Pink)
Shiel
0V (Blue)
(Red)
Open
Test input (Green)
Reset input (Yellow)
Interlock selection input (White)
Open
+24V (Brown)
+24V (Brown)
External device monitoring
input (Red)
Auxiliary output 1 (Yellow)
Safety output 1 (Green)
Safety output 2 (White)
0V (Blue)
Shield
Main Module
Control Circuit
Motor controller
(operation command)
S1
:Emergency stop switch
(direct circuit operation contact)(A165E, A22E)
S2 :Reset
switch
KM1, KM2 :Magnetic contactor
RY1, RY2 :Relay
M :3-phase
motor
E1
:24VDC power supply (S82K)
Note 1. This wiring example is for category 4.
Shield
0V (Blue)
DC24V (Brown)
DC24V (Brown)
0V (Blue)
Shield
(Red)
Test input (Green)
Reset input (Yellow)
Interlock selection input (White)
Open
Open
External device monitoring
input (Red)
Auxiliary output 1 (Yellow)
Safety
output 1 (Green)
Safety
output 2 (White)
Communication
line (+) (Grey)
Communication
line (-) (Pink)
F3SJ (2nd unit)
Emitter
Receiver
Model F39-JC A-L
cable for emitter
Model F39-JC A-D
cable for receiver
Shield
Test SW
0V (Blue)
Open (Red)
Test input (Green)
Reset input (Yellow)
Open
Interlock selection input (White)
DC24V (Brown)
Wiring when F3SJ's
testing function is used
Relay Output Module
(R Module)
Fuse
- F3SJ settings
- Auto reset mode
- Does not use external device monitoring function
- F3SX-E-L2R settings
- Manual reset mode
- Using feedback time monitoring function
Note 2. When the F3SJ is series-connected, or 5 or more sets
are connected to the total system of F3SX, power
must be supplied to F3SJ from external source.
For details, see documentation of F3SX.
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles
Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]