93
F3SJ-A
User’s Manual
Chapter
4
Wiring Examp
le
s
Input/Output Circuit and Applications
E
•Using a branch connector
Connector connection is possible using a cable with connectors on both ends and branch connector
for safety light curtains.
F3SX
Cable with connectors on both ends:
F39-JC B-L (grey)
Cable with connectors on both ends
F39-JC B-D (black)
Cable with connectors on both ends
F39-JC T for connecting to
branch connector
Grey
Black
Branch connector for
safety light curtains
F39-CN5
F3SJ
Receiver
F3SJ
Emitter
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles