To check detection, move the test rod as shown in the diagram below.
When the external test function is used:
The OFF-state indicator turns ON when the test input line is short-circuited to 9 to 24V.
When the external device monitoring function is used:
When the F3SJ is blocked and the external device monitoring input terminal is open, it enters a
lockout state.
When the start interlock function is used:
After the F3SJ is turned ON, the OFF-state indicator remains turned ON, even if the F3SJ is receiving
light. The reset switch input turns ON the ON-state indicator.
When the restart interlock function is used:
While the ON-state indicator is ON, the OFF-state indicator remains turned ON, even when the F3SJ
is blocked and then receives light again. The reset switch input turns ON the ON-state indicator.
Checking that hazardous parts stop while the machine operates
The hazardous parts stop immediately when a test rod is inserted into the detection zone at 3
positions: "directly in front of the emitter", "directly in front of the receiver", and "between the emitter
and receiver". (Use the appropriate test rod.)
The hazardous parts remain stopped as long as the test rod is in the detection zone.
The hazardous parts stop when the power of the F3SJ is turned OFF.
The actual response time of the whole machine is equal to or less than the calculated value.