11
F3SJ-A
User’s Manual
Chapter
1
Ra
tings
Overview and Specifications
E
Ratings
Ratings
/
Specifications
In the model names in this table, the
contain the 4 digits indicating the protective height (mm).
F3SJ-A
P14
F3SJ-A
P20
F3SJ-A
P30
Detection capability
Opaque objects
Opaque objects
Opaque objects
Diameter 14mm
Diameter 20mm
Diameter 30mm
Beam gap
9mm
15mm
25mm
Number of beams
26 to 234
16 to 166
10 to 100
Protective height
245 to 2,117mm
245 to 2,495mm
245 to 2,495mm
Lens diameter
Diameter 5mm
Operating range
0.2 to 9m (for protective height up to 1649 mm)
0.2 to 7m (for protective height 1655 mm or greater)
Response time
ON to OFF: 10ms to 27.5ms max., OFF to ON: 40ms to 110ms max. (when incidence is
stable).
Refer to p.14 for details.
Startup waiting time
2s max. (2.2s max in case of series connection)
Power supply voltage
24VDC ± 20% (ripple p-p10% max.)
Current consumption
(
no
load
)
Emitter
Up to 50 beams: 78 mA max., 51 to 100 beams: 113 mA max., 101 to 150 beams: 140 mA
max., 151 to 200 beams: 163 mA max., 201 to 234 beams: 177 mA max.
Receiver
Up to 50 beams: 66 mA max., 51 to 100 beams: 83 mA max., 101 to 150 beams: 101 mA
max., 151 to 200 beams: 118 mA max., 201 to 234 beams: 130 mA max.
Light source
Infrared LED (870nm wavelength)
Effective aperture angle (EAA)
Within ±2.5 ° for the emitter and receiver at a detection distance of at least 3 m according to
IEC61496-2
Safety outputs(OSSD)
PNP transistor outputs x 2, Load current 300mA max, Residual voltage 2V max. (except for
voltage drop due to cable extension), Maximum capacity load 2.2
µ
F, leakage current 1 mA
max. (This may be different from previously used logic (ON/OFF) because safety circuit is
used.)
Auxiliary output 1
(
Non-safety output
)
PNP transistor output x 1, Load current 300mA max., Residual voltage 2V max. (except for
voltage drop due to cable extension), Maximum capacity load 2.2
µ
F, leakage current 1mA
max.
External indicator output (Non-safety
output)
Connectable external indicator
- Incandescent lamp : 24VDC, 3 to 7W
- LED lamp : Load current 300mA max.
Maximum capacity load 2.2
µ
F, Leakage current 1mA max.
(An indicator cable F39-JJ3N or F39-A01P
-PAC is required when using an external
indicator.)
Output operation mode
Safety outputs : ON when receiving light
Auxiliary output 1 : Reverse output of safety output
External indicator output 1: Reverse output of safety output (for basic system), ON during
muting/override (for muting system)
External indicator output 2: ON in lockout (for basic system), ON during muting/override (for
muting system)
Input voltage
Test input, interlock selection input, reset input, external relay monitoring input, and inputs
input are all performed at the voltages below:
ON voltage: 9 to 24V (sink current 3mA max.)
OFF voltage: 0 to 1.5V, or open
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles