background image

Main  Screen

Response Time
  6-1(page10)

3sec

Detailed Settings

6

UP

UP

DOWN

DOWN

UP

DOWN

Response

50 ms

TEACH

T

50 ms

10 ms

1.5 ms

[UP] Left shift / Numerical value +

[DOWN] Right shift / Numerical value -

Output 1 Mode
  3-4(page4)

UP

DOWN

Out1 Mode

Single

TEACH

T

Single

Window BGS

Window FGS

Dist + Int *1

Displayed only when the output 2 function = Out2 Single

Displayed only when the output 2 function = Input

Output 1 
Timer Mode
  6-3(page10)

UP

DOWN

Timer Mode1

Off

TEACH

T

Off

On Delay

Off Delay

One Shot

Display Selection
  6-4(page10)

UP

DOWN

Display

Standard

TEACH

T

Standard

Simple

Bar

ON/OFF

Output 2
Timer Mode
  6-3(page10)

UP

DOWN

Timer Mode2

Off

TEACH

T

Off

On Delay

Off Delay

One Shot

Output 2 
Function
  3-2(page3)

UP

DOWN

Out2 Func.

Out1 Invert

TEACH

T

Out1 Invert

Out2 Single*3

Input

Error

External Input
  3-3(page3)

UP

DOWN

Input Func.

Laser Off

TEACH

T

Laser Off

Teach

Zero Reset

Output 1 Logic
  6-2(page10)

UP

DOWN

Out1 Logic

N.O.

TEACH

T

N.O.

N.C.

Advanced Settings

N

Y

Advanced

Settings=ON

Advanced

Settings=OFF

Advanced Settings=ON

UP

DOWN

DOWN

Adv. Setting

Off

TEACH

T

Off

On

Initialization
   5-2(page7)

DOWN

Initialize?

No

TEACH

T

No

Yes

Output 2 Logic
  6-2(page10)

UP

DOWN

Out2 Logic

N.O.

TEACH

T

N.O.

N.C.

Output 1 
Timer Time *2

UP

DOWN

Timer Time1

5

TEACH

T

1〜9999

Output 2
Timer Time *4

UP

DOWN

Timer Time2

5

TEACH

T

1〜9999

*2. Displayed only when output 1 timer mode ≠ OFF

*4. Displayed only when output 2 timer mode ≠ OFF.

Unit: ms (reference)

Unit: ms (reference)

This chart shows the transition of the menu setting screen.

If answering [Yes] to [Initialize?] and transiting to item setting, initialization is 

executed and the screen moves back to the main screen.

*1. Displayed only when background reference teaching (sensitive) is executed 

(output 1 mode = Dist + Int).

8

*3. Not displayed only when background reference teaching (sensitive) is executed 

(output 1 mode = Dist + Int).

Summary of Contents for E3AS-HL150 Series

Page 1: ...ccur Do not use the product where corrosive gases may exist Use a key lock to prevent malfunction if high pressure wash water or other substances come into contact with the button Do not apply high pr...

Page 2: ...he extension of the cord under the standard I O mode should be 100 m or less The extension of the cord in the IO Link mode should be 20 m or less Pre wired Models M12 Smartclick Connector Model M8 Con...

Page 3: ...t before zero reset execution Output after zero reset execution Output before zero reset execution Output after zero reset execution ON OFF Output1 Input Output1 Sensor response time Sensor response t...

Page 4: ...hing Object teaching Background reference teaching normal Background reference teaching sensitive 4 1 Basic Teaching page 5 4 1 Basic Teaching page 5 4 2 Advanced Teaching page 6 6 11 ABT Function pag...

Page 5: ...Background Threshold value Background reference surface Object This can be executed if setting Background when executing Teaching Selection in 6 Detailed Settings page 9 Background is the factory sett...

Page 6: ...output mode Threshold setting after teaching is completed Main screen after teaching is completed The threshold value is set with margin to the background Margin is set automatically to the optimal v...

Page 7: ...completed The unlocked icon is displayed on the main screen Setting completed The zero reset icon is displayed on the main screen Releasing completed The zero reset icon on the main screen is turned...

Page 8: ...Func Laser O TEACH T Laser O Teach Zero Reset Output 1 Logic 6 2 page10 UP DOWN Out1 Logic N O TEACH T N O N C Advanced Settings N Y Advanced Settings ON Advanced Settings OFF Advanced Settings ON UP...

Page 9: ...10page UP DOWN Interference Channel 1 TEACH T Channel 1 Channel 2 Channel 3 Channel 4 ABT Function 5 6 11 11page UP DOWN ABT Func 1sec TEACH T 1sec 0 3sec O 3min Unit mm reference Unit mm reference 6...

Page 10: ...e teaching sensitive is executed when output 1 mode Dist Int keeping is disabled The output when receiving light intensity is not su cient or detection has not been determined yet can be set 1 These a...

Page 11: ...Dist Int In the distance intensity mode user setup of hysteresis width is not allowed A xed value of 4 is always set Single Point Mode Single Window BGS mode Window BGS Window FGS mode Window FGS ON O...

Page 12: ...method E 3 A S H L M Note 1 Altitude Up to 2000m Pollution degree 3 Enclosure type Type1 1 Measured with OMRON s standard workpiece White ceramic 2 De ned by D4 method at the maximum sensing distance...

Reviews: