LVS-RIMS Quality Control Process Operations Manual Version 5.6.X
LVS-RIMS Quality Control Process Operations Manual Version 5.6.X
Page 8 of 35
4. Select
Yes
when asked, “Do you want to use the automatic setup feature?”
5. Run the web and stop when reaching the desired label(s). Pressing the F12 keyboard button allows
you to run or freeze images (see below).
Note:
Click the
“Show more”
button until you can see a complete label with at least a quarter
label either above or below the label.
6. Draw a sector slightly outside the edge of an entire label and then click the
right arrow
button. A
“Working” message appears indicating the system is analyzing the label.
Tip:
A sector is drawn by clicking on one corner of the label with your mouse, and then dragging
the mouse to opposite corner of the label. A red box will appear around the drawn sector (see below).