LVS-RIMS Quality Control Process Operations Manual Version 5.6.X
LVS-RIMS Quality Control Process Operations Manual Version 5.6.X
Page 35 of 35
7. A “Confirm Splice Prior to Here” pop-up message appears. Type “OK”
(in capital letters)
and then click the
“OK” button.
Note:
If you do not type “OK” and close the pop-up message by clicking the “X” button, the
system crashes and you must log in again and repeat the above steps.
8. Remove or replace the defective label and begin operating the Rewinder.
The red dot outlined in green indicates the beginning of a new job.
Note:
If there are error dots between the arrow on screen and the point designated by LVS, you
must manually stop the defects by stopping the Rewinder when the error dots are at the blue arrow
on screen and repair, splice, or replace the label on the second splice table.
Beginning
of a new
job.