LVS-RIMS Quality Control Process Operations Manual Version 5.6.X
LVS-RIMS Quality Control Process Operations Manual Version 5.6.X
Page 22 of 35
Dot
Description
Splice Many
The first red hollow dot indicates the start of splice many.
The last red hollow dot indicates the end of splice many.
7. When an error arrives, there will be an audible “beep” and the rewinder stops.
The operator must
choose one of the following three options:
Replace One, Splice One, or Begin Splice Many.
Note:
When the error stops short of the home position, the rewind must be jogged so that the error
dot is in the home position. At this point, the physical error will be seen in the defined error viewing
section on the rewinder.
IMPORTANT:
The error dot must be jogged to the
home position for these option buttons to be activated.
One of the option buttons must be chosen before the next
error can be viewed.
Replace One
– Remove a label and replace with another label.
Splice One
– Remove one label and then splice together the remaining labels.
Begin Splice Many
– Remove many labels and then splice together the remaining labels.
See
“Appendix A: Replacing and Splicing Options” for more information on replacing and splicing
options.
8. After one of the above buttons is selected, the thumbnail and red dots will disappear and the next defect
will appear on the thumbnail window (see figure below).