LVS-RIMS Quality Control Process Operations Manual Version 5.6.X
LVS-RIMS Quality Control Process Operations Manual Version 5.6.X
Page 12 of 35
Press Steps
Perform the following steps in the exact order as listed below.
1. Press the “Stop” button on the LVS-7000 screen.
2. Stop the press
(The press must be stopped before following the remaining steps!)
3. Click the “Print Barcode” button to print a barcode with an encoded location of the job file.
All labels must run from beginning to end with no interruption on the LVS-7000 for each roll.
4. Remove the barcode from the printer.
5. Affix the label on the web at the idler just past the light on the LVS camera
system, as indicated by the LVS barcode arrow label (see right image).
6. Jog the web until the LVS barcode label affixed to the web has traveled into the
take-up roll.
7. With the LVS barcode in the roll, remove any samples needed for your customer,
ensuring that the LVS barcode label does not get removed
from the roll
(all cuts MUST be after the LVS barcode has passed into
the take-up roll)
.
8. Press the “Start” button on the LVS-7000 screen. Turn on the press.
9. At this time, the Log File can be reviewed by Quality Control. See the next section entitled “Quality
Control Operating Steps” for steps on reviewing the Log File.
LVS® Bar Code
Arrow Label