LVS-RIMS Quality Control Process Operations Manual Version 5.6.X
LVS-RIMS Quality Control Process Operations Manual Version 5.6.X
Page 26 of 35
LVS-RIMS.INI FILE
[Rims]
A5Follows=4
Debug=0
EncoderDirection=0
EncoderPort=0
HomeToPhotoeye=12
In1= C:\Users\<username>\AppData\Roaming\Microscan\LVS 7000\Jobs
In2=\\Server2\PathToJobsDir
In3=\\Server3\PathToJobsDir
Out=\\ServerX\PathToJobsDir
LinesPerInch=400
MoveBarcodeInches=0
RewinderOffset=41500
StopDwellInMs=20
Turret=0
S
ETTING
D
EFINITION
A5Follows=4
Tells the software to use I/O Line 4 to trigger the beep.
Debug
The Debug setting is not user configurable and should not be altered unless
requested by a LVS representative.
EncoderDirection =
Can be set to 0 or 1 depending on the direction the web moves.
EncoderPort=
Determined by the encoder board’s serial port in Device Manager.
HomeToPhotoeye=
Distance in inches from the Photo-Eye to the splice table.
In1=
Tells the LVS-RIMS computer where to find QC Job files; it usually points to the
computer and directory where the QC computer saves its Jobs. For example, if
the QC computer’s IP Address is 192.168.0.102 and the
Omron Microscan
folder
was
shared, then In1 could be listed as:
In1=\\192.168.0.102\Microscan\LVS QC\Jobs
In2=
Used if there is more than one LVS-RIMS system.
In3=
Used if there is more than two LVS-RIMS systems.
Out=
Tells the LVS-RIMS computer where to save the Log files after LVS-RIMS is
complete; it usually points to the Jobs directory for LVS-RIMS. For example, it
could be listed as:
Out= C:\Users\<username>\AppData\Roaming\Microscan\LVS RIMS\Jobs
LinesPerInch=
Determined by dividing the Encoder’s pulses per revolution by the circumference
of the Encoder Wheel; this number gauges the label repeat.
MoveBarcodeInches=0
This setting alters the location of the scanned barcode to the location to be used
as the system’s HOME position. If set at 0, the barcode will be the same location
as the error presented on the screen of the LVS-7000; any changes will offset
that setting.