80-JB566-1 Rev. G
E-5
MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION
Upgrading the MCP50 Using USB Memory Sticks
Upgrading Only the MAS50 Software
4.
Remove the memory stick.
5.
Confirm the upgrade is complete by checking that it shows
SyncComplete
on the
System screen and the MCP50 software version on the Version screen. Also verify that
the VIOP is the latest revision (refer to
MAS50 External Release Notes, 70-JC513-1
).
6.
If the display shows only a blinking cursor in the top left, the USB memory stick most
likely has a separate boot sector. Remove the USB memory stick, disconnect power
until all of the VTM lights are out, and then power up again. The unit will upgrade
normally.
7.
Perform system verification.
Note
: For version CA0529R and older, it will not automatically OTA upgrade the VTM
VIOP code. Verify if it is correct. If not, call Customer Support.\