6.2.2. Photocell
6.2.2.1.
Alignment
6.2.2.2.
Functioning test
Interrupt “photocell beam” using a matt object and check”:
The alignment procedure of the photocells has to be carried
out by specialized people and authorized from the
manufacturer.
NORMAL STATUS
• RED LED ON
STOP STATUS
• RED LED OFF
POSITIONING CHECK
• With a sheet parallel to the reflector move downwards
• check when the RED LED is switched off
• mark the position
POSITIONING CHECK
• with a sheet parallel to the reflector move upwards
• check when the RED LED is switched off
POSITIONING CHECK
a) mark the position
POSITIONING CHECK
b) the work field is between the two marks
POSITIONING CHECK
c) the lift’s permitted operating field must be ±50 mm
A
With vehicle lift stopped
The lift can be not activated from the control panel
B
With vehicle lift on the go
The lift movement has to stop
PHOTOCELL
REFLECTOR