4.2
Place of installation
The free space around the lift must satisfy applicable regulations and be no less than 700 mm
or 27.5 inches.
The control unit must be positioned so that the operator has a full view over the lift
area
WORK AT A ROOM TEMPERATURE
-10° TO 40° C
14° TO 104° F.
(Indoor use Only)
To install the anchor bolts, the foundation must have the following characteristics:
FOUNDATION
Tamped
THICKNESS OF CONCRETE
≥
14 cm (6 in)
CONCRETE RESISTANCE CLASS
≥
C 25
IMPROVED ADHERENCE STEEL GIRDERS
Type Feb 44 K
REINFORCEMENT GIRDERS FOR LARGE SURFACES
Electro welded mesh
REINFORCEMENT GIRDERS FOR SMALL SURFACES
Bent irons
FLATNESS
± 1 / 1000
If the floor characteristics are not available, foundations must be provided underneath the lift
ʼ
s
base plates.
MAX. PRESSURE
(*)
Kg / cm
²
≤
6
To ensure adequate installation please refer to ANSI / ALI
ALIS SAFETY requirements for installation and service of automotive lifts