41
12 Additional equipment
It is necessary that a condensate separator and a pre-filter be installed at the inlet side and
an after-filter at the outlet side!
Condensate separator
removes liquid water and other liquid content from compressed air
flow. Removing liquid water and other liquid content with the condensate separator ensures
the efficient drying and long life of the molecular sieve.
Condensate drain
has to be installed
on the condensate separator!
Pre-filter
removes the particulate matter from the compressed air flow and extends the life
of the molecular sieve. Pre-filter should be at least ISO 8573-1 Class 6 particle filter (3 µm
particles). Install the
condensate drain
on the pre-filter housing!
After-filter
cleans the outlet air of any particulate matter originating from molecular sieve.
After-filter should be at least ISO 8573-1 Class 3 particle filter (1 µm particles). It is
recommended that all filters and the after-filter in particular be equipped with the
pressure
drop
indicator
to efficiently detect filter element clogging.
Below is the information on the recommended condensate separators, pre-filters, after-
filters and condensate drains that can be ordered as additional equipment for the
adsorption dryers.
EQUIPMENT
MODEL
DESCRIPTION
Condensate separator
CKL-B series
Condensate separators
Pre-filter
AF series P filter
Compressed air Class 6 filters
After-filter
AF series R filter
Compressed air Class 3 filters
Condensate drain
AOK16B
Automatic mechanical cond. drain
AOK20B
Automatic mechanical cond. drain up to 167 l/h
TD M/S series
Timer controlled cond. drains up to 95 l/h
EMD series
Electronic condensate drains up to 12 l/h
CDI 16B series
Electronic condensate drains up to 45 l/h
ECD-B series
Electronic condensate drains up to 150 l/h
Pressure drop indicator
PDi16
Compact differential pressure indicator
MDA60
Differential pressure indicator
MDM40
Magnetic differential manometer
MDM60
Magnetic differential manometer
MDM60E
Magnetic differential manometer, electronic, LED alarm,
battery powered
MDM60C
Magnetic differential manometer, voltage-free contact
for remote alarm
EPG60 series
Electronic pressure gauge, LED display, alarm, battery
powered, filter cartridge condition diagnostic algorithm
Contact your supplier for additional equipment details.
Summary of Contents for A-DRY Series
Page 2: ...2...
Page 16: ...16...
Page 37: ...37 5 9 1...
Page 46: ...46 13 6 13 7...
Page 48: ...48 Normally open valve Normally closed valve 13 10 13 11...
Page 50: ...50 13 15...
Page 56: ...56 14 6 14 7...
Page 63: ...63 16 Maintenance record TYPE OF MAINTENANCE DATE SIGNATURE NOTES Commissioned...
Page 64: ...64...