51
13.4 Replacement of the purge exhaust silencers
Replacement of the purge exhaust silencers:
1.
Disconnect the adsorption dryer from the compressed air system and the electrical
power.
2.
Make certain that the adsorption dryer is depressurised. You can check this by
inspecting the pressure indicators at the top of the adsorption dryer. Picture (13.16)
3.
Unscrew the purge exhaust silencers from the elbow. Picture (13.17)
4.
Screw the new purge exhaust silencers.
(13.17)
Tower 1 pressure indicator
Tower 2 pressure indicator
(13.16)