13 Maintenance
The molecular sieve, the control valves, the non-return valves and dew-point sensor are
subject to wear and need to be replaced according to the service intervals specified bellow.
PART
MAINTENANCE
1 day
1 month
1 year
2
years
4 years
Dryer operation
INSPECTION
x
Complete dryer
VISUAL INSPECTION
x
Pre/After filter element
REPLACE
x
Expansion silencer
REPLACE
x
Valves*
REPLACE
x
Adsorbent**
REPLACE
x
Dew-point sensor
(optional)
CALIBRATION
x
*Refers to moving parts and sealings.
**For stable operation replacement of adsorbent is required after every 4 years of
operation. However due to inappropriate use or unexpected inlet/operating conditions
adsorbent can be damaged sooner and in this case replacement is required sooner.
It is necessary to wear respiratory protective equipment when working with the
adsorbent. Adsorbent is a crumbling material that is producing fine dust which can
cause respiratory complications if inhaled in sufficient quantities.